Page 2
UPDATE LOG SHEET Application Data Page Part # Note(Cause & Solution) S/Bulletin # Use this page to keep any special servicing information. (Service Bulletin, etc.) If only parts number changes, Just change parts number directly on parts list. And if you need more information, please see the service bulletin...
2. Execute the Setup.exe file in the unzipped files. 3. Install as dialog box's message. 4. After completing the installation, check to run the DSCStudio.exe file in the folder where program is installed. * Generally, it is created in C:\Program files\Samsung\DSCStudio. Samsung Electronics...
Page 4
About TAP : • Camera Adjustment I : (see Figure 5) •Camera Adjustment II : (see Figure 6) • View Graphic File : (see Figure 7) •Test Options : (see Figure 8) • PGM for Manufacturing : (see Figure 9) Samsung Electronics...
Page 5
*Note - The model set value is 007 in the PGM mode. However, error occurred when 80 sets are connected to adjust. - Make sure that the testing model is the same with the running model in program. Samsung Electronics...
Page 6
• The JPEG image can be displayed without any image edit program. 1. Click the Open button to display the file saved as a JPEG format. 2. Click the Slid Show button to display the file containing in the option at an specified interval. Samsung Electronics...
Page 7
The settings of the Test Options (see Figure 7) are applied as a sequence. Click the START button to run. The edit function is enabled when Vs appear in the check boxes of Enable Scroll Inspect Item Window and Enable Scroll Information Window. Samsung Electronics...
Menu bar type control for each status Transmission Mode PC interfacing only mode - Direct interfacing mode Others - Manual adjust mode : adjusting exposure - Navigation key control : 4-direction movement and selection The technical specifications and design may be changed without notice. Samsung Electronics...
Page 12
Disassemblr and Reassembly 3-1-4. Ass’y CASE-FRONT Removal Remove 2 screws. Remove the CASE-FRONT. * Be careful to assemble MACRO-LEVER with LENS-MACRO when assembling the case-front. Fig. 3-4 Ass’y CASE-FRONT Removal Samsung Electronics...
Page 13
Disassemblr and Reassembly 3-1-6. Ass’y MAIN Removal Remove the ASSY-MAIN. Remove the 3screws. Remove the FPC-MAIN from MAIN-PCB. Fig. 3-6 Ass’y MAIN Removal Samsung Electronics...
3. After running the program for adjustment on the PC to click the Focus Mode On button in the Camera Adjustment mode. 4. Repeat step 3 through 5 of “Adjusting in the Photo Mode”. 5. Click the Focus Mode On button and finish the program for adjustment. Samsung Electronics...
Page 19
2. One adjustment point is TP1-MCLK. Adjust using CT301. 3. Connect probe of frequency counter with TP1. 4. Using CT301, adjust it so that MCLK is 54.00MHz+00Hz. (External view of PCB :Main Board component side) 5-1-3. Program for Adjustment Samsung Electronics...
Page 20
2) - Connect the probe of oscilloscope to TPL1-VB. - Press the UP/DOWN button or the number buttons so that the B level is 3.5 ± 0.1Vp-p. 3) Using the UPDATE button, store the adjusted value in the EEPROM. Samsung Electronics...