Note:
During conversion to LPG, a flue gas orifice plate must also be installed in the condensate pan as follows. This installation
step is carried out prior to the installation of the mixing chamber and full assembly.
7)
After removing the upper casing cover, undo the self-
tapping screw at the balanced flue locking mechanism.
8)
Slide the balanced flue locking mechanism in the direction
of the arrow. Pull the flue pipe up out of the condensate
pan.
Conversion type plate
Conversion sets for CGB-75/100 for conversion to other gas types: (Please state the corresponding part number when ordering)
Conversion to LPG P (G31)
* ID imprinted on gas restrictor
24
Conversion to other gas types
(if required)
9)
10)
Part no. 86 12 714
Flue gas orifice plate
Place the flue gas orifice plate Ø 53 mm into the condensate
pan and insert the flue pipe again.
Note:
During conversion from LPG to natural gas, the
flue gas orifice plate must be removed. Fit the
mixing chamber as described under point 6).
Re-assemble in reverse order.
Updating the type plate
Cut out the relevant lines from the type plate supplied
and affix them over the relevant lines on the appliance
type plate.
Figure: Updating the type plate
ID 740*
30 62 555_0709