Thank you for purchasing TOA's Zone Manager.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

1. GENERAL DESCRIPTION

The ZM-9001 is a remote control switch panel used with the 9000 Series amplifiers.
It adds 6 control inputs and can be mounted in a 1-gang electrical box (American type).
The ZM-9002 is a remote control switch/volume panel used with the 9000 Series amplifiers.
It adds 4 control inputs and 1 volume control, and can be mounted in a 1-gang electrical box
(American type).

2. NOMENCLATURE AND FUNCTIONS

2.1. ZM-9001

[Front]
[Rear]
1
2
1
E OUT
3
4
5
6

2.2. ZM-9002

[Front]
[Rear]
1
2
3
E OUT
3
4
4
0
OPERATING INSTRUCTIONS
ZM-9001, ZM-9002
1. Control buttons [1 – 6]
Activate the function assigned to them when
pressed.
2
2. Control output terminal [E, OUT]
Connect this terminal to the 9000 Series
amplifier's REMT VOL terminal.
Use a shielded cable with 50 Ω or less line
resistance (per line) for this connection.
Avoid installation of this cable and power cables
in the same conduit. Separate piping.
3. Control buttons [1 – 4]
Activate the function assigned to them when
pressed.
4. Volume control
Adjusts the volume on the assigned input or
5
output channel.
5. Control output terminal [E, OUT]
Connect this terminal to the 9000 Series
amplifier's REMT VOL terminal.
Use a shielded cable with 50 Ω or less line
resistance (per line) for this connection.
Avoid installation of this cable and power cables
in the same conduit. Separate piping.

3. CONNECTIONS

Connecting the ZM-9001 Zone Manager to the 9000 Series amplifier adds 6 control inputs and
allows the equipped 6 control buttons to perform the functions assigned for input's or output's
channel volume up/down, or other functions.
Connecting the ZM-9002 Zone Manager to the 9000 Series amplifier adds 1 volume control and 4
control inputs. Volume of the input or output channels can be remotely adjusted with the volume
control, and the 4 control buttons can be assigned the same functions as those of the ZM-9001.
Function assignment to the control buttons or volume control is performed at the 9000 Series
amplifier. For the method, refer to the instruction manual supplied with the 9000 Series amplifier.
9000 Series amplifier
CTRL
I/O
REMT
IN
VOL1
E
IN
E
REMT
1
VOL2
2
3
IN
4
E
1
2
OUT
3
4
E
REMT VOL terminal
IN
REMT VOL1
(Remote volume 1)
E
IN
REMT VOL2
(Remote volume 2)
E
Note
One ZM-9001 or one ZM-9002 can be
connected to each of the REMT VOL1 and
2 terminals.
ZM-9001
1
2
3
OUT
4
E
5
6
ZM-9002
1
2
OUT
3
E
4
Volume control

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZM-9001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Toa ZM-9001

  • Page 1 Volume of the input or output channels can be remotely adjusted with the volume control, and the 4 control buttons can be assigned the same functions as those of the ZM-9001. Function assignment to the control buttons or volume control is performed at the 9000 Series Thank you for purchasing TOA's Zone Manager.
  • Page 2 [Dimensions of mounting opening] Traceability Information for Europe (EMC directive 2004/108/EC) 1-gang electrical box (American type, not supplied) Manufacturer: Authorized representative: TOA Corporation TOA Electronics Europe GmbH 7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo, Suederstrasse 282, 20537 Hamburg, Japan Germany 46 – 50 URL: http://www.toa.jp/...

This manual is also suitable for:

Zm-9002

Table of Contents