Technical data
Spray arms, turning rhythm at alternating spray
system
Turning starts every time with the upper spray arm
Pre wash
Lower arm ~3min, Upper arm ~1min
Main wash Lower arm ~3min, Upper arm ~5min
Intermediate rinse
Lower arm ~2min, Upper arm ~2min
Final rinse Lower arm ~2min, Upper arm ~2min
Service Test program
Lower arm ~30sec, Upper arm ~30sec
Remark: When switching of the main switch or
interrupt the mains during the Test Program runs,
then the alternating of the spray arms change in
the test program to the rhythm of main wash 5/3
min.
Important: To leaf the Test program is possible by
made a break by customer (pushing the start
button for 1.5 sec.)
After finishing the test program (End LED shines
and/or Start LED goes of) must the appliance be
switched off.
If this will not be done, then the next normal wash
will be made with the frequency of the Service
Test Program ~30/30sec.
Electrical base data
Voltage
Frequency
Total power
Fuse
Spray pump motor alternating spray system
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Power consumption
Resistance
Heating - 1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat self reset
(Temperature of water)
Fuse
Whirlpool Europe
Customer Service
240
V
50
Hz
2.4
kW
10
A
220/ 240 V
125
W
79
60
µ F
4
220/ 240 V
30
W
146
240
V
2.22
kW
24.5
~ 2.0
˚C/min
~ 115
˚C
~ 85
˚C
206
˚C
ADP 6940 WHM
8542 940 53929
Single electric water inlet valve
Voltage
Frequency
Resistance
Motor Diverter Valve
Voltage
Frequency
Resistance
Signal (2x within ~13 sec.) 5.0
Coil of dispenser
Voltage
Frequency
Resistance
Reed contacts
flow meter
rinse aid control
Optical water indicator (OWI)
Optical measurement of the water in sump
Combination part of:
Turbidity sensor
Thermostat temp. sensor (notice NTC)
NTC
20 ˚C
25 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
Accesory
If you need spare parts apart from the spare part
list have a look in the
Service Bulletin 4812 718 40084.
For higher mounted Dishwashers to prevent the
drain off effect - also usable for lower drain pipes
and to prevent the failure F8 use
Kit 4812 310 18993.
15.12.2006 / Page 3
Doc. No: 4812 728 13954
220/ 240 V
50/ 60
Hz
3.76
kΩ
220 - 240 V
50/ 60
Hz
6.5
kΩ
V
220/ 240 V
50/ 60
Hz
1.3
kΩ
(DON)
58.1
kΩ
47 .1
kΩ
38.2
kΩ
25.4
kΩ
17 .2
kΩ
11.8
kΩ
8.3
kΩ
6
kΩ
4
kΩ