NOTE FOR REPAIR
• Make sure that the flat cable and flexible board are not cracked of bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
• When remove a connector, don't pull at wire of connector. It is possible that a wire is snapped.
• When installing a connector, don't press down at wire of connector.
It is possible that a wire is snapped.
• Do not apply excessive load to the gilded flexible board.
NOTE FOR DISCONNECTION THE HARNESS (COAXIAL CABLE)
Tweezers etc.
GV-HD700/HD700E_L2
2. DISASSEMBLY
When disconnecting the harness (coaxial cable), do not pull the
harness part but pull off the connector body with tweezers etc.
Harness
(coaxial cable)
2-1
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)