American Aldes HRV95SRD Operation And Installation Manual

Premium series

Advertisement

HRV95SRD
TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION
Installing Contractor _________________________________________Telephone / Contact _____________________
Serial Number______________________________________________Installation Date ________________________
Model _________________________________________________________________________________________
prevents unwanted use of the dehumidistat when outdoor temperatures exceed 15°C (59°F).
Installation and wiring to be in accordance with CEC, NEC
and local electrical codes.
Important: Read and save these instructions.
Operation and Installation Manual
Premium Series
HRV155SRD
HRV200SRD
HRV120SRD
LEAVE FOR HOMEOWNER
New Auto Dehumidistat Function
INSTALLER: Leave this manual for the homeowner
ERV200S
HRV300DDD
69-ALD-01
0709

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HRV95SRD and is the answer not in the manual?

Questions and answers

Summary of Contents for American Aldes HRV95SRD

  • Page 1 Operation and Installation Manual Premium Series HRV155SRD ERV200S HRV95SRD HRV200SRD HRV300DDD HRV120SRD LEAVE FOR HOMEOWNER TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION Installing Contractor _________________________________________Telephone / Contact _____________________ Serial Number______________________________________________Installation Date ________________________ Model _________________________________________________________________________________________ New Auto Dehumidistat Function prevents unwanted use of the dehumidistat when outdoor temperatures exceed 15°C (59°F).
  • Page 2: Table Of Contents

    Table of Contents Warranty..................2 CAUTION Technical Data - Model HRV95SRD ...........3 Port Configuration and Airflow - Model HRV95SRD ....4 Technical Data - Model HRV120SRD .........5 Before installation, careful consideration must be Technical Data - Model HRV155SRD .........6 given to how this system will operate if connected Technical Data - Model HRV200SRD .........7...
  • Page 3: Technical Data - Model Hrv95Srd

    Model HRV95SRD ENGINEERING DATA Performance (HVI certified) THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Net supply air flow in cfm (L/s) against external static pressure The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed E.S.P for cleaning or service.
  • Page 4: Port Configuration And Airflow - Model Hrv95Srd

    Port Configuration and Airflow Model HRV95SRD HRV95SRD Port Specifications In order to make the HRV95SRD as space efficient as possible, the INDOOR supply and return ports are converted from round to oval The Heat Recovery Ventilator (HRV) has been designed to allow shape.
  • Page 5: Technical Data - Model Hrv120Srd

    Model HRV120SRD ENGINEERING DATA THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Performance (HVI certified) The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for Net supply air flow in cfm (L/s) against external static pressure cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure)
  • Page 6: Technical Data - Model Hrv155Srd

    Model HRV155SRD ENGINEERING DATA THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for Performance (HVI certified) cleaning or service. Net supply air flow in cfm (L/s) against external static pressure MOTORS AND BLOWERS E.S.P Each air stream has one centrifugal blower driven by a common PSC motor.
  • Page 7: Technical Data - Model Hrv200Srd

    Model HRV200SRD ENGINEERING DATA Performance (HVI certified) THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Net supply air flow in cfm (L/s) against external static pressure The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed E.S.P for cleaning or service. (external static pressure) [cfm (L/s)] MOTORS AND BLOWERS...
  • Page 8: Technical Data - Model Hrv300Ddd

    Model HRV300DDD ENGINEERING DATA Performance THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE (HVI certified) Net supply air flow in cfm (L/s) against external static pressure The cross-flow heat recovery core transfers heat between the two airstreams. The two cores are E.S.P arranged for highly efficient counter current airflow. (external static pressure) [cfm (L/s)] MOTORS AND BLOWERS...
  • Page 9: Technical Data - Model Erv200S

    Model ERV200S ENGINEERING DATA LATENT RECOVERY/MOISTURE TRANSFER CORE Performance (HVI certified) The cross-flow energy recovery core transfers heat and water vapor between the two Net supply air flow in cfm (L/s) against external static pressure airstreams. It is easily removed for cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure)
  • Page 10: Glossary

    Controlling your HRV/ERV HOW MUCH VENTILATION DO I NEED? Today's modern, tight homes require fresh outdoor air to maintain a healthy indoor air environment. The amount of ventilation you During seasons when your windows and doors are closed (winter, require in your home will depend upon: and summer if air conditioned), the HRV/ERV should be set to operate continuously on low speed with the option of going to high •...
  • Page 11: The Premium Series Digital Control Model Adxc-Ii

    The Premium Series Digital Control MODEL ADXC-II MODEL ADXC-II THE PREMIUM SERIES DIGITAL CONTROL Instruction card (INCLUDED WITH UNIT) OFFERS MANY Fan Speed ADVANCED FEATURES Indicator Key Features Humidity 20/40/60 Minute Indicator • 2 Speed Fan setting (Low-1/High-2) High Speed Override Button •...
  • Page 12: The Premium Series Programmable Control Model Apv

    The Premium Series Programmable Control MODEL APVC MODEL APVC Instruction card The Optional Premium Programmable Control fully digital and allows you to program when and how much fresh Fan Speed Date & Time Indicator air enters your home. Humidity Key Features 20/40/60 Minute Indicator High Speed...
  • Page 13: Optional Timers

    Optional Timers Depending on the type of HRV/ERV installation, you may have timers in areas such as restrooms. The timer will override the Operational Mode (regardless of the setting) and initiate high speed ventilation. Upon completion of the timer cycle, the HRV/ERV will return to your selected Operational Mode and speed setting DET-II 20/40/60 Minute Timer...
  • Page 14: Installation Methods

    Installation Methods The Three Methods of Installation Installing the Ducting Between the HRV/ERV & Living Areas in the House The three methods of installation for the HRV/ERV system are: • The Simplified installation. A well designed and installed ducting system will allow the HRV/ERV to operate at its maximum efficiency.
  • Page 15: Installation Diagrams

    Simplified Installation Diagrams Simplified Installation (Return/Return Method) Key Points • The HRV/ERV must be balanced. • It is mandatory that the furnace blower run continuously or HRV/ERV operation be interlocked with the furnace blower. • The duct configuration may change depending on the HRV/ERV model.
  • Page 16 Partially Dedicated Installation Diagrams Partially Dedicated System This installation enables stale air to be drawn from the poorest air quality areas of the home (bathrooms, kitchen). Key Points • The HRV/ERV must be balanced. • It is recommended that the furnace blower run continuously or HRV/ERV operation be interlocked with the furnace blower to evenly distribute the fresh air throughout the...
  • Page 17 Fully Dedicated Installation Diagrams Fully Dedicated System This is a stand alone HRV/ERV system which is not connected to a force air system. Stale air is drawn from key areas of the home (bathroom, kitchen) while fresh air is supplied to main living areas Key Points •...
  • Page 18: Installation

    Installation Location Illustration of Suspending the HRV/ERV The HRV/ERV must be located in a heated space where it will be possible to conveniently service the unit. Typically the HRV/ERV would be located in the mechanical room or an area close to the outside wall where the weatherhoods will be mounted.
  • Page 19: Engineering Data Hrv

    Engineering Data - HRV Model HRV120SRD Option 1 - Horizontal Duct Configuration Dimensions inches STALE FRESH AIR FROM AIR TO OUTSIDE OUTSIDE HANGING STRAPS STALE AIR FROM BUILDING FRESH AIR TO BUILDING 25 1/8” (637 mm) BOTTOM VIEW FOR HORIZONTAL MOUNT SERVICE CLEARANCE FROM BOTTOM STALE AIR OF UNIT IS MINIMUM 3’0”...
  • Page 20: Suspending The Hrv120Srd

    Suspending the HRV120SRD Model HRV120SRD ATTENTION Horizontal Installation The unit must be mounted level for proper drainage of the condensate pans. JOIST FASTENERS (not supplied) STRAPS SCREWS (supplied) DETAIL Using full length hanger straps is recommended for vibration control, but can be shorter if required.
  • Page 21: Drain Connection

    Drain Connection Drain Connection DRAIN HOSE PLUMBING The HRV may produce some condensation during a defrost PRE-PUNCHED HOLES (2) cycle. This water should flow into a nearby drain, or be taken away by a condensate pump. DRAIN PAN DRAIN PAN CAUTION DRAIN DRAIN...
  • Page 22: Weatherhood Installation

    Weatherhood Installation Installing the Ducting from the Weatherhoods Weatherhoods to the HRV/ERV Fixed covered weatherhoods have a built-in bird screen with a 1/4" (6mm) mesh to prevent foreign objects from entering the The inner and outer liners of the flexible insulated duct must be ductwork.
  • Page 23: Installation Of The Main Control

    Installation of the Main Control Premium Series Controls may be installed onto a flush mounted 2" x 4" electrical switch box or it may be surface mounted onto a wall. Pay special attention not to damage the Contact Only 1 master control should be installed to a ventilation system Pins when attaching and detaching the Face Plate.
  • Page 24: Installation And Operation 20/40/60 Minute Timers

    Installation and Operation 20/40/60 Minute Timers MODEL DET - II Operating your DET-II 20/40/60 Minute Fan Timer Press and release the Select Button to activate a 20, 40 or 60 minute high speed override cycle. The High Speed Status Light will illuminate and the unit will run on high speed High Speed ventilation for the selected time.
  • Page 25: Installation Of Zrt Zone Register Terminal

    INSTALLATION OF ZRT Zone Register Terminal Roller switches on the ZRTs are “Dry Contacts”. Connect the two red roller switch wires to the ON and HI terminals. Connect a jumper wire between the ON and RED terminals. (Refer to Illustration.) Jumper Wire Optional...
  • Page 26: Interlocking Hrv/Erv To An Airhandler/Furnace Blower

    Interlocking the HRV/ERV to an Air handler/Furnace Blower Connecting the HRV/ERV as illustrated will ensure the Air CAUTION Handler/Furnace Blower Motor is operating whenever the HRV/ERV is ventilating. Consideration must be given to competing airflows when connecting the HRV/ERV in The HRV/ERV must be interlocked to the Furnace/Air conjunction with an Air Handler/Furnace Blower Handler with a Simplified Installation (Return/Return...
  • Page 27: Pitot Tube Air Flow Balancing

    Pitot Tube Air Flow Balancing It is necessary to have balanced air flows in an HRV/ERV. The Insert the Pitot tube into the duct; pointing the tip into the airflow. volume of air brought in from the outside must equal the volume For general balancing it is sufficient to move the pitot tube around of air exhausted by the unit.
  • Page 28: Air Flow Measuring Kit

    AIR FLOW MEASURING KIT is used, it may be advisable to insert the Amplifl ow sensor into a The American ALDES airfl ow measuring kit is designed to measure short collar of metal duct. airfl ow accurately in ducting. Utilizing the Amplifl ow sensor by Nailor-...
  • Page 29: Balancing Collar Instructions

    Balancing Collar Instructions Push and turn with slotted screwdriver. Damper When connecting ductwork automatically locks when to the collar, take note where pressure is released. screws are located. Screws should be located no further than 1/2” from outside edge Hard/Rigid of collar, so as not to impede ducting operation of the damper.
  • Page 30: Maintenance Routine For Your Hrv/Erv

    Maintenance Routine for HRV/ERV 1. Inspect Exterior Hoods at least once a month. NOTE: Core will appear to stick out from cabinet approximately 1/8” (3mm). This is designed this way so that the access door will fit tight Make sure exhaust and fresh air supply hoods are not blocked or against the core.
  • Page 31: Troubleshooting Your Hrv/Erv System

    Troubleshooting your HRV/ERV System SYMPTOM CAUSE SOLUTION Poor Air Flows • 1/4” (6 mm) mesh on the outside hoods is plugged • clean exterior hoods or vents • filters plugged • remove and clean filter • core obstructed • remove and clean core •...
  • Page 32: Wiring Diagrams

    Residential Wiring Diagram Model HRV120SRD LEGEND HIGH VOLTAGE Thermistor 12V LOW VOLTAGE (Not on all units) BLUE BLACK GREEN WHITE AUTO- DEFROST TRANSFORMER DETAIL BLACK WHITE Note: If any of the original AUTO-TRANSFORMER DETAIL PINS 1, 2 AND 3 ARE OPTIONAL wire supplied with the unit Motors PLUG IN CONNECTOR...
  • Page 33: Wiring Diagrams

    Residential Wiring Diagram HRV95SRD, HRV155SRD, HRV200SRD, HRV300DDD, ERV200S LEGEND HIGH VOLTAGE Thermistor 12V LOW VOLTAGE (Not on all units) BLUE BLACK GREEN WHITE AUTO- TRANSFORMER DEFROST DETAIL GREEN Note: If any of the original wire supplied with the unit must be replaced, use only TEW certified wire.
  • Page 34: Heat And Energy Recovery Ventilator Warranty

    LIMITATIONS OF WARRANTY AND LIABILITY This warranty does not apply to any AMERICAN ALDES product or part which has failed as a result of faulty installation or abuse, incorrect electrical connections or alterations made by others, or use under abnormal operating conditions or misapplication of the product or parts.