Trigger In
In the System settings menu, press the Power input select button to
enter the submenu. Press the Trig In input select button to enable the
function.
Trig In
Mode
Auto PwD
Power
Press the Mode button to exit the submenu.
Auto Power Down (APD)
In the System settings menu, press the Power input select button to
enter the submenu. Pressing the Auto PwD input select button will scroll
through the options of 2 hours, 1 hour, 30 mins, 15 mins, 10 mins, 5
mins and Auto PwD (disabled).
Trig In
Mode
Auto PwD
Power
Press the Mode button to exit the submenu.

CAP5: Five-way protection system

Cambridge Audio has developed a proprietary protection system to
When the 851E and the 851W are paired, if any, the 851E can detect
851E LCD display.
To achieve this, connect the 'Control Bus Out' from the 851W to the
'Control Bus In' on the 851E.
851E
851W
1. W DC Offset – DC detection
Indicator – Unit has switched off during operation.
Description – CAP5 offers loudspeaker protection if the output of the
although detecting it could just save those expensive loudspeakers.
Remedy – Due to the necessary sensitivity of the DC protection circuit,
If this fault occurs please switch the unit off, power up again and check
operation with a reduced volume level. If the DC fault occurs again
please contact your dealer for service.
14
2. W Overtemp – Over temperature detection
Indicator – Unit has switched off during operation.
Description – CAP5 includes temperature detection which constantly
monitors the heat generated by the output transistors. If the monitored
temperature reaches a high level (suitably within the limits of the output
a cabinet or the ventilation slots are obstructed, the over-temperature
detection may activate/reactivate after a short listening time.
Volume
Remedy – The unit is not damaged, although it should be left for 15
minutes to cool down before being switched out of Standby.
3. W Overload – Overvoltage/overcurrent detection
Indicator – Unit has switched off during operation.
Description – CAP5 offers V/I protection by constantly monitoring the
output transistors to keep them working inside their Safe Operating
Area (SOA). The SOA is a set of limits given by the output transistor
short-circuits on the speaker terminals during use.
Remedy
Reduce the volume. Also check to see if there is a short- or partial short-
circuit between the loudspeaker terminals.
Volume
Note: If the indication remains the same and multiple loudspeakers are
being used on each loudspeaker output, then please remove a pair and
will detect this situation. If the indication remains the same with only one
set of loudspeakers connected, there may be a fault with one or both of
the loudspeakers.
4. W Skp shrt – Short-circuit detection
Indicator – As the unit attempts to come out of Standby mode.
Description – During power up from Standby, CAP5 performs a check
on the loudspeaker terminals to see if a short across the terminals has
been accidentally introduced. If the resistance measured across the
loudspeaker terminals is too low, the unit will remain in Standby mode
until the fault has been removed and power up is re-attempted.
Remedy – User-related fault. There may be a short-circuit between
the loudspeaker terminals. Check all loudspeaker connections before
attempting to switch the unit out of Standby.
5. W Clipping – Intelligent clipping detection
Indicator – Volume is nudged down automatically. Note that this
automatic function will only work if the 'Vol Clipping' is enable in the
Input sub menu.
Description
to clip or overdrive at its output, which can damage loudspeakers and
degrade the sound. Clipping distortion is caused at high volume levels
When CAP5 detects clipping, the volume will be automatically nudged
down until CAP5 detects an undistorted output.
The clipping detection is disabled by default. However, to enable the
clipping detection, hold down the Standby/On button during power up
(whilst switching on the unit at the rear panel power switch). The unit will