Activox XYC100B-SPT Operator's Manual

Portable oxygen concentrator
Hide thumbs Also See for XYC100B-SPT:

Advertisement

Operator's Manual
For Use with models:
XYC100B-sPt & XYC100B-Pro
Manufactured & Distributed by
www.InovaLabs.com

Advertisement

Table of Contents
loading

Summary of Contents for Activox XYC100B-SPT

  • Page 1 Operator’s Manual For Use with models: XYC100B-sPt & XYC100B-Pro Manufactured & Distributed by www.InovaLabs.com...
  • Page 2 Copyright © 2014 Inova Labs, Inc. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from Inova Labs Inc. Inova Labs Inc.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Introduction Application/Indications For Use Symbol Descriptions Warnings Contraindications Adverse Events/Hazards Standard Package Contents User Controls Part Names Operating Instructions Battery Life Timetable Carry Case Configuration Instructions Flying With Your POC Operating Procedure Light Indicators/Alarms Routine Cleaning and Maintenance Service Life Technical Support Disposal...
  • Page 4: Introduction

    It is not life-supporting nor life-sustaining. It may be used continuously in a home, institution or travel environment. The LifeChoice Activox is also portable. This device should be used only when prescribed by a physician.
  • Page 5: Symbol Descriptions

    SymBOL DESCRIPTIONS Symbol Description Symbol Description Symbol Description Consult Caution instructions for No smoking Do not No open flame No oil or grease disassemble Temperature Humidity Keep dry limit limitation Compliant with Fragile, handle This side up with care WEEE Date of Class II Manufacturer...
  • Page 6: Contraindications

    CONTRAINDICATIONS 1. The device is not intended to be life-sustaining or life-supporting. 2. In certain circumstances, oxygen therapy can be hazardous. Please seek medical advice before using this device. 3. The device is designed to provide a flow of high purity oxygen up to 3 LPMeq pulse.
  • Page 7: Standard Package Contents

    STANDARD PACkAGE CONTENTS AC Power Adapter LifeChoice Activox POC 4-Way Carry Case DC Power Adapter Use as a backpack, shoulder strap, waist pack or briefcase Standard 7-Foot (2-meter) Long Adjustable Straps Single Lumen Nasal Cannula† For use with 4-Way Carry Case...
  • Page 8: User Controls

    Setting Control Buttons on the Control Panel: 1, 2, and 3 which reference oxygen flow. Use the setting prescribed by your doctor. Power Button: To turn the LifeChoice Activox POC on or off, press the Power Button. Auto mode Indicators: There are two inhalation sensitivity modes on the control panel: Active-High and Sleep-Low, which automatically adjust based on oxygen demand (e.g.
  • Page 9 Battery Charge Indicator: The Battery Charge Indicator consists of four LEDs labeled “25%”, “50%”, “75%”, and “100%”. Battery Check LED Charge Level 25% LED 50% LED 75% LED 100% LED 1% -12%* Blinking 13% - 25% 26% - 37% Blinking 38% - 50% 51% - 62% Blinking...
  • Page 10: Part Names

    PART NAmES Cannula Nozzle Fitting Fan Inlet vent Control Panel Fan Outlet vent External Battery Port FAA Approval Sticker (located on bottom) Cannula Nozzle Fitting: The Nasal Cannula connects to the oxygen output nozzle at the top of the POC. DO NOT place the cannula into nasal passages until the POC is fully powered on.
  • Page 11: Operating Instructions

    OPERATING INSTRUCTIONS The LifeChoice Activox POC is recommended and designed to be operated and stored in its carry case at all times. To configure the carry case as a backpack, please reference the Carry Case Configuration Instructions. FOLLOW THESE STEPS BEFORE FIRST USE: 1.
  • Page 12 OPERATING INSTRUCTIONS continued 2. AC Adapter/Charger: An AC Adapter/Charger allows the POC to be powered from a standard 100-240 VAC, 50/60 Hz outlet. When the unit is operated from an AC Adapter/Charger, power from the AC outlet powers the unit and recharges the internal and/or External Battery.
  • Page 13 OPERATING INSTRUCTIONS continued 3. It can take a fully discharged Internal Battery up to 4.5 hours with the Pro Model or 3 hours with the Sport Model to reach a 100 percent charge level. Press the Battery Check button to check the charging process.
  • Page 14: Battery Life Timetable

    OPERATING INSTRUCTIONS continued 4. When the External Battery is fully charged, the EXT Battery Check LED will turn off. NOTE: The charge indicator will show 4 solid green lights when the battery has a charge level of 96 percent or more. When the battery reaches a full 100 percent charge, the EXT LED will turn off.
  • Page 15: Carry Case Configuration Instructions

    6. Adjust straps as needed. Assistance may be required with this step. FLyING WITH yOUR POC The LifeChoice Activox POC is approved by the FAA for use on commercial aircraft. This approval is listed as a part of the labeling on the bottom panel of the unit.
  • Page 16: Operating Procedure

    2. Power the POC using one of the four modes described in the Powering the LifeChoice Activox POC section. 3. Press the Power Button once to turn the unit on. An audible beep will sound and the Power LED, the Auto Mode Active-High LED and the Pulse Setting of 1 LED will flash green.
  • Page 17 5. Select a Pulse Setting of 1, 2, or 3 as prescribed by your doctor. The device utilizes PULSE-WAVE™ Delivery which delivers oxygen congruent with your inhalation rate. Because this type of delivery is very gentle, you may not feel the pulse of oxygen. To verify that oxygen is being delivered, reference the LED above your selected Pulse Setting.
  • Page 18: Light Indicators/Alarms

    LIGHT INDICATORS/ALARmS NORmAL OPERATION INDICATORS Normal Audible Light Indication Action Operation Alert Brief You may begin to POC turned audible use the POC unit in tone 3 minutes Green LEDs of Power, Active-High and Pulse Setting 1 are illuminated. NOTE: After the initial power on, the Pulse Setting LED corresponding to the last flow rate used will illuminate POC has...
  • Page 19 ALARm INDICATORS Audible Problem Light Indication Action Alert Check cannula No breath connection. Breathe detected by Intermit- through nose and the unit for tent beep alarm will shut off. approximately If alarm persists, 75 seconds contact your Amber Alarm LED light flashes provider.
  • Page 20: Routine Cleaning And Maintenance

    ROUTINE CLEANING AND mAINTENANCE The LifeChoice Activox POC was designed to minimize the amount of routine maintenance that is required. The device does not have any end-user repairable parts. Aside from the preventative maintenance outlined below, all other maintenance required must be performed by qualified personnel.
  • Page 21: Service Life

    SERvICE LIFE This section outlines the defined service life of the LifeChoice Activox POC’s components. The service life of these components is dependent on operating and environmental conditions. Daily use of the unit may actually extend the replacement time for some of these items. It is recommended that the device be powered on and run for a few hours, if it is has not been used on a daily basis.
  • Page 22: Oxygen Concentration Over Altitude And Flow Rate

    Power Supply: AC 100 to 240 VAC, 50 to 60 Hz; DC 11 to 16 VDC or Battery 12 to16.8 VDC LifeChoice Activox POC Input: 19VDC, 6A External AC Power Adapter/Charger Input: 100-240VAC, 50 - 60 Hz; Output: 19VAC, 6.3A External DC Power Adapter/Charger Input: 11-16VDC, 10A;...
  • Page 23: Accessories

    Included with purchase of LifeChoice Activox POC. Product Number: XYC340 External Battery Not included with purchase of LifeChoice Activox POC Standard Package. Product Number: 200122 *Accessories, adapters, and cables other than those specified, with the exception of adapters and cables sold by the manufacturer of the medical electrical equipment as replacement parts for internal components, may result in increased emissions or decreased immunity of the Model XYC100B/XYC100B-SPT/XYC100B-PRO.
  • Page 24: Warranty

    WARRANTy LImITED WARRANTy AND DISCLAImER (“Limited Warranty”) NOTE: This Limited Warranty provides specific legal rights. The Purchaser may also have other rights which vary from state to state or country to country and in some cases, due to applicable laws, certain limitations or exclusions of this Limited Warranty may not apply.
  • Page 25 WARRANTy continued The Limited Warranty extends only to the Purchaser and is not transferable unless otherwise expressly agreed to in writing by Inova Labs. Inova Labs’ oxygen concentrators produce enriched oxygen gas which accelerates combustion. DO NOT ALLOW SMOKING OR OPEN FLAMES within ten (10) feet (three (3) meters) of these devices while in use.
  • Page 26 WARRANTy continued to conform to the Limited Warranty set forth herein, Purchaser must give prompt written notice to Inova Labs (with such notice in no event beyond the applicable warranty period), at which time Inova Labs or its authorized distributor will issue a Return Material Authorization (“RMA”) number. All Items claimed to be defective within the warranty period shall be properly packaged and shipped on a prepaid basis to Inova Labs (USA sales) or its authorized distributor at Purchaser’s expense.
  • Page 27 WARRANTy continued FORm OF THE CLAIm, WHETHER IN CONTRACT, TORT, NEGLIGENCE, STRICT LIABILITy OR OTHERWISE, ARISING OUT OF OR RELATING TO INOvA LABS’ ITEmS, mATERIALS AND/OR SERvICES, AND EvEN IF INOvA LABS HAS BEEN ADvISED OF THE POSSIBILITy OF SUCH DAmAGES.
  • Page 28: Emc Information

    Activox Portable Oxygen Concentrator Model XYC100B- ® SPT/XYC100B-PRO is intended for use in the electromagnetic environment specified below. The customer or the user of the Model XYC100B-SPT/XYC100B-PRO should assure that it is used in such an environment. Immunity Test IEC 60601...
  • Page 29 Activox Portable Oxygen Concentrator Model XYC100B- ® SPT/XYC100B-PRO is intended for use in the electromagnetic environment specified below. The customer or the user of the Model XYC100B-SPT/ XYC100B-PRO should assure that it is used in such an environment. Immunity Test...
  • Page 30 Activox Portable Oxygen Concentrator Model XYC100B- ® SPT/XYC100B-PRO is intended for use in the electromagnetic environment specified below. The customer or the user of the Model XYC100B-SPT/ XYC100B-PRO should assure that it is used in such an environment. Emissions Test...
  • Page 31 OWNER’S NOTES...
  • Page 32 Manufactured & Distributed by 3500 Comsouth Drive, Suite 100, Austin, Texas 78744 USA Corporate Office 1.512.617.1700 | www.InovaLabs.com © 2014 Inova Labs Inc. All rights reserved. Made in the USA. 12M-015 REV B Feb 2014...

This manual is also suitable for:

Xyc100b-prXyc100b-pro

Table of Contents