Note For Multi System - Daikin Inverter CTXS09DVJU Operation Manual

Daikin room air conditioner inverter type
Hide thumbs Also See for Inverter CTXS09DVJU:
Table of Contents

Advertisement

Note for Multi System

〈〈 What is a "Multi System"? 〉〉
This system has one outdoor unit connected to multiple
indoor units.
■ Selecting the Operation Mode
1. With the Priority Room Setting present but
inactive.
When more than one indoor unit is operating, priority is
given to the first unit that was turned on.
In this case, set the units that are turned on later to the
same operation mode (*1) as the first unit.
Otherwise, they will enter the Standby Mode, and the
operation lamp will flash; this does not indicate
malfunction.
(*1)
• COOL, DRY and FAN mode may be used at the same time.
• AUTO mode automatically selects COOL mode or HEAT mode based on the room temperature.
Therefore, AUTO mode is available when selecting the same operation mode as that of the room
with the first unit to be turned on.
〈CAUTION〉
Normally, the operation mode in the room where the unit is first run is given priority, but the following
situations are exceptions, so please keep this in mind.
If the operation mode of the first room is FAN Mode, then using Heating Mode in any room after this will give priority to
heating. In this situation, the air conditioner running in FAN Mode will go on standby, and the operation lamp will flash.
2. With the Priority Room Setting active.
See "Priority Room Setting" on the next page.
■ NIGHT QUIET Mode (Available only for cooling operation)
NIGHT QUIET Mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the nighttime hours to
prevent annoyance to neighbors.
• The NIGHT QUIET Mode is activated when the temperature drops 9°F or more below the highest temperature
recorded that day. Therefore, when the temperature difference is less than 9°F, this function will not be activated.
• NIGHT QUIET Mode reduces slightly the cooling efficiency of the unit.
■ OUTDOOR UNIT QUIET Operation (page 15.)
1. With the Priority Room Setting present but inactive or not present.
When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all indoor units
to OUTDOOR UNIT QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.
2. With the Priority Room Setting active.
See "Priority Room Setting" on the next page.
■ Cooling / Heating Mode Lock
The Cooling / Heating Mode Lock requires initial programming during installation. Please consult your authorized
dealer for assistance. The Cooling / Heating Mode Lock sets the unit forcibly to either Cooling or Heating Mode. This
function is convenient when you wish to set all indoor units connected to the Multi system to the same operation mode.
22
Outdoor
unit
A
room
room
■English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Inverter ctxs09gvjuInverter ctxs12gvjuCtxs09dvjuCtxs09gvjuCtxs12gvju

Table of Contents