3. POWER AMPLIFIER ADJUSTMENT
Idling Current Alignment
1. Each of the measurement points are provided with the two
test points. Set a digital Voltage meter to DC voltage input,
connect the meter to the test points at both contact points.
2. After the setup above, turn on the main switch.
3. Adjust variable resistors (VR60 - VR66) according to the
digital voltmeter readings. The target setting value is the
following table for each channels.
Settings :
Master Volume- - - - Minimum
Speaker out - - - - - No Load
Top lid - - - - - - - - - - OPEN
VR63
DC voltmeter
NO.
Channel
1
Surround Right
2
Surround Left
3
Center
4
Front Left
5
Surround Back Left
6
Front Right
7
Surround Back Right
DC
VOLTMETER
+
TEST POINT
3
2
1
CN70
CN71
CN74
VR64
VR65
HEAT SINK ASS'Y
Measurement
Alignment
Point
point
CN70
VR63
CN71
VR64
CN74
VR65
CN72
VR60
CN75
VR61
CN73
VR66
CN76
VR62
MAIN PWB
CUP12206Z
4
5
CN72
CN75
VR60
VR61
VR66
Time Table of Idling Current Rise
After Turning ON
5 min
10 min
20 min
30 min
40 min
50 min
60 min
15
s
6
7
CN73
CN76
VR62
Measurement Voltage
(CN7X)
7.5 mV
0.5 mV
7.5 mV
0.5 mV
7.5 mV
0.5 mV
7.5 mV
0.5 mV
7.5 mV
0.5 mV
7.5 mV
0.5 mV
7.5 mV
0.5 mV