1. Contents of Remote Controller Switch Alarm Display

Remote controller is
Serial
detecting error signal from
communication
indoor unit.
errors
Mis-setting
Indoor unit is detecting error signal from remote controller (and system controller).
Indoor unit is detecting error
signal from outdoor unit.
Outdoor unit is detecting error
signal from indoor unit.
Improper setting
Improper setting
Indoor unit communication
error of group control wiring.
During auto address setting,
number of connected units
does not correspond to
number set.
3
Improper setting
Indoor unit
Thermistor
fault
Possible cause of malfunction
Error in receiving serial communication signal.
(Signal from main indoor unit in case of group control)
(Auto address is not completed.)
Error in transmitting serial communication signal.
Error in receiving serial communication signal.
When turning on the power supply, the number of connected
indoor units does not correspond to the number set.
(Except R.C. address is "0.")
Error in receiving serial communication signal.
There is an indoor unit which does not send signals when
the power is ON.
Indoor unit address setting is duplicated.
Duplicated remote controller "main" setting.
Automatic address setting start is prohibited.
AP pin was short-circuited at time when automatic
address setting was started.
Error of main indoor unit in receiving serial communication
signal from sub indoor units.
Number of connected indoor units is less than the number
set.
Number of connected indoor units is more than the number
set.
No indoor unit is connected during auto address setting.
Duplicated outdoor unit address.
Mismatch in "No. of outdoor units" setting.
Connected indoor unit is not a multi unit.
Duplication of main indoor unit address setting in group
control.
Duplicated indoor unit priority (priority indoor unit).
Duplicated indoor unit priority (non-priority indoor unit) and
outdoor unit.
Group control wiring is connected to individual control
indoor unit.
Indoor unit address is not set.
Capacity code of indoor unit is not set.
Mismatch of outdoor unit type.
Duplication of outdoor R.C. address setting.
Capacity code of outdoor unit is not set.
Indoor coil temp. sensor (E1)
Indoor coil temp. sensor (E3)
Indoor suction air (room) temp. sensor (TA)
Indoor discharge air temp. sensor (BL)
3 - 2

Trouble Diagnosis

ON:
Blinking:
OFF:
Wired
Wireless
remote
remote controller
control
receiver display
display
<E01>
Operating
lamp blinking
<E02>
<<E03>>
E04
Heating ready
lamp blinking
<E06>
E08
<<E09>>
Operating
lamp blinking
E12
E18
E15
Heating ready
E16
lamp blinking
E20
E25
E26
L02
<L03>
L05
Operating and heating
ready lamps blinking
L06
simultaneously
L07
L08
<<L09>>
L17
Operating and heating
L04
ready lamps blinking
simultaneously
L10
<<F01>>
Operating and timer
lamps blinking
<<F03>>
alternately
<<F10>>
<<F11>>