stepping-motor is defective (or its drive circuit on the main PCB). The color wheel is not
located in the default position after the reset.
04Er:
(Rotating gobo-wheel error ) This message will appear after the reset of the fixture if the
magnetic-indexing circuit malfunctions(sensor failed or magnet missing) or the
stepping-motor is defective (or its drive circuit on the main PCB). The rotating gobo-wheel is
not located in the default position after the reset.
05Er
(Rotating gobo indexing error) This message will appear after the reset of the fixture and if
the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driver circuit on the main PCB). The rotating gobo is not
located in the default position after the reset.