OWNER'S MANUAL TUB-MASTER IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
INSTALLATION & OPERATING INSTRUCTIONS GENERAL Your AQUA-FLO pump has been quality built and engineered to give maximum efficiency under normal water pumping conditions. Consult the manufacturer for any other applications. LOCATION OF PUMP For best pump performance, locate the system as close to the water source as possible.
Page 3
FLO-MASTER "TMCP" REPLACEMENT PARTS ® REF. PART NO. DESCRIPTION Motor 92770603 Volute, TMCP Series 92500150 Seal, Replacement, #200 *See Chart Below * Impeller 92200270 O'ring, Volute, #251 92830062 Wear Ring 56910050 Cover Assembly, Suction Tub-Master Replacement Impeller & Wet End Guidelines To order a replacement part, ALWAYS use the part number molded on the impeller being replaced, if available.
ARNING LECTRIC HOCK PERFORMING ANY WORK ON THE PUMP UNIT To Disassemble Pump AUTION RAIN THE WATER FROM THE PLUMBING LINES BEFORE DISCONNECTING THE PUMP MOTOR FROM POSSIBLE WATER DAMAGE Removing the Suction Cover 1. Remove the cover by removing the screws securing the cover to the volute (casing). These screws are located at the perimeter of the cover.
Page 5
with ceramic ring. Caution: Do not grip impeller sleeve. 3. Reinstall the wear ring over the impeller hub in correct orientation. Reinstalling the Suction Cover 1. Inspect the o-ring for damage. Replace if necessary. 2. Properly install the o-ring on the cover before mounting the cover to the volute. 3.
Need help?
Do you have a question about the Tub-Master Series and is the answer not in the manual?