8.17. Remove the Plasma panel sec-
tion from the Cabinet assy
1. Place the Cabinet assy on a flat surface of a table (cov-
ered by a soft cloth) and a cushion.
2. Remove the Bottom cabinet assy. (See section 8.16.)
3. Remove the screws (×6
4. Remove the Plasma panel section from the Cabinet assy.
, ×13
).
8.18. Remove the Contact metals
1. Remove the Cabinet assy. (See section 8.17.)
2. Remove the Tape from the Contact metals.
3. Remove the screws (×6
4. Remove the Contact metal side (L, R).
5. Remove the screws (×6
6. Remove the Contact metal top.
7. Remove the screws (×15
8. Remove the Contact metal bottom.
8.19. Remove the C1-Board
1. Remove the Contact metal bottom. (See section 8.18.)
2. Disconnect the flexible cables (CB1, CB2, CB3, CB4,
CB5, CB6 and CB7).
3. Disconnect the flexible cables (C10 and C11).
4. Disconnect the connector (C14).
5. Remove the screws (×4
25
TC-P42GT30A
).
).
).
) and remove the C1-Board.