Other Features - Heat Controller BHD-H Series Owner's Manual

Portable dehumidifier
Table of Contents

Advertisement

Owner's Manual
Display
8
Shows the set % relative humidity level from 35% to
85% or the auto start/stop time (0~24 hours) as it is
being set. Also shows the actual room humidity level
in a range of 30% RH (Relative Humidity) to 90%RH
(Relative Humidity) with an accuracy of +5%.
Error Codes and Protective Features:
AS- Humidity sensor error--Unplug the unit and plug it
back in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and

OTHER FEATURES

Bucket Full Light
Illuminates when the bucket is ready to be emptied, or when
the bucket is removed or not seated in the proper position.
Auto Shut Off
The dehumidifier shuts off after 30 seconds when the
bucket is full, or when the bucket is removed or not
seated in the proper position. When the set humidity is
reached, the unit will shut off automatically. For some
models, the fan motor will continue operating. Exception
Does not apply in continuous operation.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to run
until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restarted in the
first 3 minutes. This is to protect the unit. Operation will
automatically occur after 3 minutes.
Check filter feature
The system starts to count the time once the fan motor
operates. The check filter feature can be only activated
when the accumulated operation time achieves 250
hours or more. The Reset light(Clean filter indicator
light) flashes one time per second. After cleaning the air
filter, press the Filter pad to turn the filter light (clean filter
indicator light) off the time resets.
Turbo Light
Illuminates when the fan speed is set up to Turbo mode.
Normal Light
NOTE: Applies to models without built-in pump only.
Illuminates when the fan speed is set to normal, which is
low fan speed.
Continuous Light
NOTE: Applies to models with built-in pump only.
Illuminates when continuous operation is in effect.
BHD-H/ BHDP-H Portable Dehumidifier
5
plug it back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position--
Empty the bucket and replace it in the right position.
Eb- The bucket has been removed from the unit or
is not in the right position. Replace or reposition the
bucket properly.
EC- Unit malfunction--Ensures the unit is operating
within the design parameters for temperature. If this
error occurs, turn off the unit and turn on again to
reset. If this error occurs after powering off and back
on call for service.
Auto-Restart
If the unit turns off unexpectedly due to power outage,
it will restart with the previous function setting automa-
tically when the power resumes.
Setting the Timer
• When the unit is on, first press the Timer button, the
Timer Off indicator light illuminates. It indicates the
Auto Stop program is initiated. Press it again the Time
On indicator light illuminates. It indicates the Auto Start
is initiated.
• When the unit is off, first press the Timer button, the
TIMER ON indicator light illuminates. It indicates the
Auto Start program is initiated. Press it again the Time
Off indicator light illuminates. It indicates the Auto Stop
is initiated.
• Press or hold the UP or DOWN pad to change the Auto
time by 0.5 hour increments, up to 10 hours, then at 1
hour increments up to 24 hours. The control will count
down the time remaining until start.
• The selected time will register in 5 seconds and the
system will automatically revert back to display the
previous humidity setting.
• When the Auto start & Auto stop times are set,
within the same program sequence, TIMER ON OFF
indicator lights illuminate identifying both ON and OFF
times are now programmed.
• Turning the unit ON or OFF at any time or adjusting
the timer setting to 0.0 will cancel the Auto Start/Stop
function.
• When LED display window displays the code of P2,
the Auto Start/Stop function will also be cancelled.
Heat Controller

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bhdp-h seriesR-410a

Table of Contents