AC power

Warning!
For protection from electric shock, the fixture must be grounded (earthed). The power
supply shall have overload and ground-fault protection.
Important! Verify that power supply settings match the local AC supply before use.
The MX-10 Extreme is factory configured for 230 V / 50 Hz operation. If your AC power
supply is different, the fixture must be configured for the local voltage and frequency.
Always use the voltage settings that are equal to or next highest to your AC supply.
T O C O N F I G U R E F O R L O C A L A C P O W E R
1 Disconnect the fixture from power.
2 Remove the 4 cover screws with a 5 mm hex key. Lift off the front cover.
3 Locate the selection switches and the settings label, which is by the color wheel. Move the voltage switch to
the setting that is equal to or higher than the local AC voltage. If your voltage falls between 2 settings,
always select the higher voltage. For example, if the AC voltage is 215 V, use the 230 V setting instead of
210 V.
4 Move the frequency switch to the setting that matches the local AC frequency: 50 or 60 Hz.
5 Replace the cover.
8
Figure 2: Power supply settings