Cleaning And Service - Nordic EFFECTA LAMBDA 35 Installation, Maintenance, Service, Assembly

Ecolabeled wood boiler
Table of Contents

Advertisement

Cleaning and service

Cleaning interval
1. Loading compartment 40 hours firing.
2. Tubes 40 hours firing.
3. After burning chamber 15 hours firing.
4. Fan about 3 times a year.
5. Cleaning lambda sensor once per year.
6. Air distributor secondary air 40 hours firing.
7. Combustion chamber.
8. Check the gaskets once per year.
9. Flue connection elbow.
10. The holes where the primary air is released once
per year.
Tubes
In order to clean the tubes, lift the rear top plate
(1.), then loosen the wing nuts (2.), that keep the
soot door in place (3.). Remove the 7 spirals from
the tubes (4.), and use the supplied brush to clean
the tubes.
Loading compartment
Start by removing the pin (1.) located at the bottom of the
ceramics. Scrape off the coals and ash down into the slits in
the ceramics. The loading compartment walls (2.) normally
have a thin layer of tar, this is normal and does not need
to be scraped off. Do not forget to check that there are no
ashes in the hole where the primary air (3.) is released into
the loading compartment.
Afterburner chamber and combustion chamber
The afterburner chamber (1.) is located
behind the lower door. It is important to
keep it clean for maximum power and
performance. The chamber slides on two
rails under the ceramics tray. Pull out
and empty the chamber from soot and
ashes approximately every third firing.
When you do a major cleaning, scrape the
space under the ceramics clean as well
as the whole space where the afterburner
chamber is located. Do not forget to reach
all the way into the back where the ashes from
the tubes collect.
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46 (0)300 22320 - info@effecta.se