7-2-6 TEMPERATURE COMPENSATION & OVERCOOLING/UNDERCOOLING
COMPENSATION CIRCUIT
1.
Refrigerator Temperature Compensation
Resistance
(RCR1)
Table of Temperature Compensation by adjusting the resistance (Difference with the current
temperature).
Example. If the refrigerator compensation resistance (RCR1) is changed from 10 K (the current
resistance) to 18 K (the adjustment resistance) of the refrigerator rises 33.8°F (+1°C).
Refrigerator
Temperature
Compensation
°F
41
180 KW
39.2
56 KW
37.4
33 KW
35.6
18 KW
35.24
12 KW
32
10 KW
30.2
8.2 KW
28.4
5.6 KW
26.6
3.3 KW
24.8
2 KW
23
470 KW
Remark
(°C)
(+5.0)
Compensation by raising
the temperature
(+4.0)
(+3.0)
(+2.0)
(+1.8)
( 0 )
Standard Temperature
( -1.0 )
Compensation by
lowering the temperature
( -2.0 )
( -3.0 )
( -4.0 )
( -5.0 )
29