Carrier 25HNB5 Installation Instructions Manual

Infinity 15 heat pump with puron refrigerant 1-1/2 to 5 nominal tons (sizes 18-60)
Hide thumbs Also See for 25HNB5:

Advertisement

Installation Instructions
SAFETY
CONSIDERATIONS
Improper
installation,
adjustment,
alteration,
service,
maintenance,
or use can cause explosion,
fire, electrical
shock, or
other
conditions
which
may
cause
death,
personal
injury,
or
property
damage.
Consult
a qualified
installer,
service
agency,
or
your
distributor
or branch
for information
or assistance.
The
qualified
installer
or agency
must use factory-authorized
kits or
accessories
when modifying
this product.
Refer to the individual
instructions
packaged
with the kits or accessories
when installing.
Follow
all safety codes. Wear safety glasses,
protective
clothing,
and work
gloves.
Use quenching
cloth
for brazing
operations.
Have
fire
extinguisher
available.
Read
these
instructions
thoroughly
and
follow
all warnings
or cautions
included
in
literature
and
attached
to the unit. Consult
local building
codes
and current
editions
of the
National
Electrical
Code
( NEC
)
NFPA 70.
In Canada,
refer to current
editions
of the Canadian
electrical
code CSA 22.1.
Recognize
safety information.
This is the safety-alert
symbol/_
When
you
see this symbol
on the unit
and in instructions
or
manuals,
be alert to the potential
for personal
injury.
Understand
these
signal
words;
DANGER,
WARNING,
and
CAUTION.
These words
are used with
the safety-alert
symbol.
DANGER
identifies
the most
serious
hazards
which
will result
in severe
personal
injury
or death.
WARNING
signifies
hazards
which
could
result
in personal
injury
or death.
CAUTION
is used to
identify
unsafe
practices
which
would
result
in minor
personal
injury
or product
and
property
damage.
NOTE
is used
to
highlight
suggestions
which
will result in enhanced
installation,
reliability,
or operation.
ELECTRICALSHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
injury or death.
Before
installing,
modifying,
or servicing
system,
main
electrical
disconnect
switch
must
be
in
the
OFF
position.
There
may be more than 1 disconnect
switch.
Lock out and tag switch with a suitable warning
label.
IMPORTANT:
Always
install the factory-supplied
liquid-line
filter drier.
Obtain
replacement
filter driers from
your distributor
or branch.
INSTALLATION
RECOMMENDATIONS
NOTE:
In some cases noise in the living
area has been traced
to gas pulsations
from improper
installation
of equipment.
1. Locate
unit away from windows,
patios,
decks, etc. where
unit operation
sound may disturb
customer.
2. Ensure
that vapor
and liquid
tube diameters
are appropri-
ate for unit capacity.
3. Run refrigerant
tubes as directly
as possible
by avoiding
unnecessary
turns and bends.
4. Leave some slack between
structure
and unit to absorb vi-
bration.
5. When
passing
refrigerant
tubes
through
the
wall,
seal
opening
with
RTV or other
pliable
silicon-based
caulk.
(See Fig. 1.)
6. Avoid
direct tubing
contact
with
water pipes,
duct work,
floor joists, wall studs, floors, and walls.
7. Do not suspend
refrigerant
tubing
from joists
and studs
with
a rigid wire or strap
which
comes in direct contact
with tubing.
(See Fig. 1.)
8. Ensure
that
tubing
insulation
is pliable
and completely
surrounds
vapor tube.
9. When
necessary,
use hanger
straps which
are 1 in. (25.4
mm) wide and conform
to shape of tubing
insulation.
(See
Fig. 1.)
10. Isolate
hanger
straps
from
insulation
by
using
metal
sleeves bent to conform
to shape of insulation.
NOTE: Avoid contact between tubing and structure
THROUGH
THE WALL
CUT HAZARD
I
Failure
to follow
this caution
may result in personal
injury.
I
Sheet metal parts may have sharp edges or burrs. Use care and I
wear
appropriate
protective
clothing
and
gloves
when
handling
parts.
IMPORTANT:
Maximum
liquid-line
size is 3/8-in.
OD for all
residential
applications
including
long line.
SUSPENSION
Fig. 1 -
Connecting
Tubing
Installation
A94028