KB Series Condensing
RU80i, RU80e, RU98e, RU98i
SW1 Bank
OFF - "Long Flue"
ON - "Short Flue" and Outdoor Models
1
"Long flue" is defined as:
0 elbows and length is greater than 21 ft
1 elbow and length is greater than 15 ft
2 elbows and length is greater than 9 ft
2
Settings dependent on altitude
3
0-2000 ft
2001-5200 ft
(0-610 m)
(610-1585 m)
#2: OFF
#2: OFF
#3: OFF
4
OFF (Air Handler)
OFF - 120ºF fixed temperature without a controller
5
ON - 140ºF fixed temperature without a controller
OFF - 120ºF maximum temperature
without an MCC-91-2 controller
6
ON - 140ºF maximum temperature
without an MCC-91-2 controller
7
OFF (Units in standby with EZConnect™)
8
OFF
SW2 Bank (present on replacement PC boards only)
OFF - Propane Gas
1
ON - Natural Gas
2
OFF (Optional Temperature Table)
3
OFF (Optional Temperature Table)
4
OFF (Recirculation Pump)
5
OFF
ON for RU80
6
OFF for RU98
7
OFF
8
OFF (Recirculation - Insulation)
Condensing Water Heater Service Manual
KB Series Dip Switch Settings
5201-7700 ft
(1585-2347 m)
#2: ON
#3: ON
#3: OFF
7701-10200 ft
(2347-3109 m)
#2: ON
#3: ON
* RU80i, RU80e, RU98e, RU98i models
have a default maximum temperature of
120º F (49º C) and an option to increase
the maximum temperature to 140 ºF (60
ºC). Temperature settings from 125-140
ºF (52-60 ºC) are available by setting dip
switch 6 to ON in the SW1 bank of 8 dip
switches.