Thermostat Chart - Single Stage Ac With Psc Furnace - York 13 Seer-TCG Installation Manual

Outdoor split-system air conditioning
Table of Contents

Advertisement

AC 5D
Single Stage Air Conditioner – Single Stage PSC Furnace
THERMOSTAT
*PP11C70224
Y
Full Stage Compressor
RH
24 – Volt Hot
(Heat XFMR)
G
Fan
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
HM1
Humidistat
Clipping Jumper W914 for
electric heat on thermostat
is not necessary
FIGURE 12: Thermostat Chart - Single Stage AC with PSC Furnace
Johnson Controls Unitary Products
G*(8/9)S
L(Y/M)8S
24VAC Humidifier
(Optional)
ID MODELS
GF(8/9)
G*9F
LF8
TG(8/9)S
G8C
(G/T)GLS
SINGLE STAGE
PSC
FURNACE
SINGLE STAGE PSC
1
FURNACE
C
24 – Volt Common
Y/Y2
Full Stage Compressor
R
24 – Volt Hot
G
Fan
W
Full Stage Heat
Other Part Numbers:
1
SAP =
Legacy
265901 = 031-09166
835964-UIM-A-0112
SINGLE STAGE
AIR
CONDITIONER
SINGLE STAGE
SINGLE STAGE
AIR CONDITIONER
AIR CONDITIONER
C
24 – Volt Common
Y
Y
Compressor Contactor
Compressor
11