2.
With the SRPT-30/40A TRANSMIT/STANDBY switch in "STANDBY" position, plug the transmitter into a
grounded, three-prong, 110-120 or 220-240 VAC outlet.
THE MANUAL SWITCH ON THE INTERNAL SWITCHING POWER SUPPLY IS SET AT THE
FACTORY TO THE 115 POSITION IF THE ORDER WAS FOR 110-120 VAC.
THE MANUAL SWITCH ON THE INTERNAL SWITCHING POWER SUPPLY IS SET AT THE
FACTORY TO THE 230 POSITION IF THE ORDER WAS FOR 220-240 VAC.
IF THE OPERATOR PLANS TO OPERATE THIS UNIT AT AN AC VOLTAGE DIFFERENT THAN
WHAT IS STATED ON ORDER, IT IS THE REPONSIBILITY OF THE PURCHASER TO SWITCH TO
DO NOT PLUG INTO AC WITHOUT FIRST KNOWING THE POSITION OF THE AC INPUT SWITCH
LOCATED ON THE SIDE OF THE INTERNAL POWER SUPPLY.
SEE AC LINE INPUT SELECTION – 110-120 VAC OR 220-240 VAC SUB-SECTION IN THE
CALIBRATION AND ADJUSTMENTS SECTION FOR VERIFICATION AND CHANGING.
THIS EQUIPMENT MUST BE OPERATED WITH A 3-PRONG, GROUNDED, 110-120 OR 220-240
FAILURE TO USE A PROPERLY GROUNDED OUTLET COULD RESULT IN A SAFETY HAZARD
IF AN EXTENSION CORD IS USED, IT MUST BE THE THREE-WIRE GROUNDING TYPE TO
WARNING
THE APPROPRIATE POWER SUPPLY POSITION.
WARNING
WARNING
VOLT AC OUTLET RECEPTACLE!
OR FAULTY EQUIPMENT PERFORMANCE.
INSURE SAFETY.
8/7/2003
9