9.3.2 QS2

QQ
3 7 63 1515 0
7 Acquisition of panel operation data • • • [QS2]
The command QS2 is for acquiring data on the panel's operational information.
Command
Format
[QS2]
All operations
Data Arrangement
ECO
1
Notification of mode shifting to STB
2
Flag for adjustment of the main unit
3
Flag for adjustment-data backup
4
"1st PD" data
5
"2nd PD" data
6
Still picture detection
7
Reserved
8
Temperature data (TEMP 1)
9
SD main data
10
SD sub data
11
Operation status induced by SD
12
Data from the hour meter
13
MASK indication
TE
L 13942296513
CS
Note : (*1) The unit scale is centigrade. The data is A/D value from the
thermal sensor.
(*2) "00000259" of "Data from the hour meter" means
2 hours 59 minuts.
1: Notification of mode
shifting to Standby
Entering Standby
0
mode failed
Entering Standby
1
mode succeeded
2: Adjustment of the
main unit
0
Adjustment completed
Adjustment not
1
completed
3: Adjustment-data
backup
www
0
With backup data
1
No data (default)
.
5
http://www.xiaoyu163.com
Effective Operation
Modes
To acquire data on operations of the panel Return data: 3 (ECO)+23(DATA)+2(CS)= 28 Byte
Data
Length
3 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
2 Byte
3 Byte
1 Byte
1 Byte
1 Byte
8 Byte
1 Byte
2 Byte
4, 5: PD data
0
No PD data
1
Not used
2
POWER
3
SCAN
4
SCN-5V
5
Y-DRV
6
Y-DCDC
7
Y-SUS
8
ADRS
9
X-DRV
A
X-DCDC
B
X-SUS
C
Not used
D
Not used
E
Not used
x
ao
y
F
UNKNOWN
i
http://www.xiaoyu163.com
6
8
Function
6: Still picture
Output Example
QS2
0
1
1
0
9: SD main data
0
0
0
1
0
2
0
∗∗
3
4
128 (*1)
0
10-1: SD-Sub (SQ-IC)
0
0
0
1
00000259 (*2)
2
0
Q Q
3
3
6 7
1 3
4A
6
10-2: SD-Sub (IIC)
0
1
2
3
11: Operation status
0
1
2
u163
.
PDP-5016HD
6
7
2 9
9 4
2 8
Remarks
detection
Normal screen
Still picture
No SD
SQ-IC
MDU-IIC
RST2
TEMP
No SD-Sub data
Communication error
Drive stop
BUSY
1 5
0 5
8
2 9
9 4
Version mismatching
10-3: SD-Sub (TEMP)
No SD-Sub data
0
EEPROM
1
BACKUP
2
DAC
13: MASK indication
induced by SD
0
Normal
1
Relay-off completed
During warning
indication
m
co
7
8
9 9
A
B
C
2 8
9 9
D
No SD-Sub data
TEMP1
Reserved
E
MASK-OFF
MASK-ON
F