5-11 RECEIVE SENSITIVITY ADJUSTMENT (continued)
1) Select an adjustment item (band) using [2] / [8].
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
[469.9 MHz*]
[470.1 MHz*]
[535.1 MHz*]
[599.9 MHz*]
[600.1 MHz*]
[780.1 MHz*]
[999.9 MHz*]
; This output level of a standard signal generator (SSG) is indicated as SSG's open circuit.
*; This frequency is an example only, and may differ from the actual frequency displayed on the function display.
ITEM
20 • Set the SSG as;
Frequency
Level
21 • Set the SSG as;
Frequency
Level
22 • Set the SSG as;
Frequency
Level
23 • Set the SSG as;
[Tr]
Frequency
Level
24 • Set the SSG as;
Frequency
Level
25 • Set the SSG as;
Frequency
Level
26 • Set the SSG as;
Frequency
Level
OPERATION
: 469.9 MHz
: –3 dBµ (–110 dBm)
: 470.1 MHz
: 0 dBµ (–107 dBm)
: 535.1 MHz
: 0 dBµ (–107 dBm)
: 599.9 MHz
: 0 dBµ (–107 dBm)
: 600.1 MHz
: 0 dBµ (–107 dBm)
: 780.1 MHz
: 0 dBµ (–107 dBm)
: 999.9 MHz
: 0 dBµ (–107 dBm)
5 - 11
VALUE
Push
[BAND].
(Automatic
adjustment)