2a) 5VDC CB K9 Connector Continued:
a) Control Switch"DRAIN" Position
CB K9 connector pins #1 (W/BK) and #2 (W/BK):
• "ICE" Position: When the control switch is in the "ICE" position, CB K9 connector
pin #1 and pin #2 are open. 5VDC is present between CB K9 connector
pin #1 (W/BK) and pin #2 (W/BK). If not, confirm 5VDC between pin #1 (W/BK) and
CB red K4 connector, pin closest to CB black K3 connector. If 5VDC is not present,
replace CB.
• "DRAIN" Position: When control switch is in the "DRAIN" position, CB K9 connector
pin #1 (W/BK) and pin #2 (W/BK) are closed. 5VDC is present between both CB
K9 connector pin #1 (W/BK) and pin #2 (W/BK) to CB red K4 connector, pin closest
to CB black K3 connector. If 5VDC is not present, replace CB.
b) High-Pressure Switch (HPS)
CB K9 connector pins #3 (Y) and #4 (Y): When HPS is closed, 5VDC is present
between both CB K9 connector pins #3 (Y) and pin #4 (Y) to CB red K4 connector
pin closest to CB black K3 connector. If 5VDC is not present on pin #3 (Y) or pin
#4 (Y), replace CB. If 5VDC is present on CB K9 connector pin #3 (Y) and not on CB
K9 connector pin #4 (Y), HPS is most likely open. CB sounds a 3-beep alarm. Check
HPS continuity. If HPS is open and CB is not in alarm, replace CB.
c) Compressor Delay Relay (CDR)
CB K9 connector pins #5 (W/O) and #6 (W/O): When CDR is de-energized (GM off),
CDR terminals #3 and #5 are open and 5VDC is present between CB K9 connector
pin #5 (W/O) and CB K9 connector pin #6 (W/O). If 5VDC is not present, check CDR
continuity between terminals #3 and #5. If open, replace CB. When CDR is energized,
CDR terminals #3 and #5 close and 0VDC is present between CB K9 connector pin
#5 (W/O) and pin #6 (W/O). 5VDC is present between CB K9 connector pin #5 (W/O)
to CB red K4 connector pin closest to CB black K3 connector and CB K9 connector
pin #6 (W/O) to CB red K4 connector pin closest to CB black K3 connector. If GM is
energized and CDR terminals #3 & #5 are open, an 8-beep alarm occurs. See "III.B.
LED Lights and Audible Alarm Safeties." If CDR terminals #3 and #5 are closed
and 0VDC is present between CB K9 connector pin #5 (W/O) and pin #6 (W/O),
5-min. Comp delay timer starts. If Comp does not energize after 5-min. delay timer
terminates, replace CB.