Carrier 50KQA Product Data page 17

Console water source heat pumps
Table of Contents

Advertisement

COOLING — EAT 80 F DB/67 F WB
EWT F
GPM
TC
TSC
1.7
10.8
7.8
2.3
10.9
7.8
40
3.0
10.9
7.8
1.7
10.4
7.6
50
2.3
10.5
7.6
3.0
10.5
7.7
1.7
10.0
7.4
60
2.3
10.1
7.5
3.0
10.2
7.5
1.7
9.7
7.3
70*
2.3
9.8
7.3
3.0
9.8
7.4
1.7
9.3
7.2
80
2.3
9.4
7.2
3.0
9.5
7.2
85*
2.3
9.2
7.1
1.7
9.0
7.0
90
2.3
9.0
7.0
3.0
9.1
7.0
1.7
8.6
6.8
100
2.3
8.7
6.9
3.0
8.7
6.9
1.7
Operation Not Recommended
110
2.3
8.3
6.7
3.0
8.3
6.7
LEGEND
DB
— Dry Bulb
EWT
— Entering Water Temperature (F)
GPM
— Gallons per Minute
MBtuh — Btuh in Thousands
— Total Capacity
TC
THA
— Total Heat of Absorption (MBtuh)
THR
— Total Heat of Rejection (MBtuh)
TSC
— Total Sensible Cooling (MBtuh)
WB
— Wet Bulb
WLHP — Water Loop Heat Pump
*ARI 320 points (bold printing) are shown for comparison purposes
only. These are not certified data points.
50KQA,KQD009 (
3
Sensible/
kW
THR
Total Ratio
0.72
0.47
12.4
0.72
0.45
12.4
0.72
0.44
12.4
0.73
0.51
12.2
0.73
0.49
12.2
0.73
0.48
12.2
0.74
0.56
11.9
0.74
0.55
12.0
0.74
0.54
12.0
0.75
0.63
11.8
0.75
0.61
11.9
0.75
0.60
11.9
0.77
0.69
11.7
0.76
0.67
11.7
0.76
0.66
11.7
0.77
0.72
11.7
0.78
0.77
11.6
0.78
0.74
11.6
0.77
0.73
11.6
0.79
0.84
11.5
0.79
0.83
11.5
0.79
0.81
11.5
0.81
0.91
11.4
0.80
0.89
11.4
/
TON) — RATED AIRFLOW 280 CFM
4
HEATING — EAT 70 F DB
TC
kW
THA
Operation Not Recommended
8.1
0.66
5.9
8.2
0.67
6.0
9.0
0.70
6.7
9.3
0.70
6.9
9.4
0.71
7.0
10.2
0.73
7.7
10.4
0.73
7.9
10.6
0.74
8.1
11.3
0.77
8.7
11.7
0.78
9.0
11.9
0.79
9.2
12.6
0.82
9.8
12.9
0.82
10.1
13.2
0.84
10.3
Operation Not Recommended
NOTES:
1.
Shaded boxed areas represent KQD units only.
2. MOPD = Maximum Operating Pressure Differential (water pres-
sure differential at unit cannot exceed MOPD or water valve cannot
close).
3. Interpolation is permissible, extrapolation is not.
4. All entering air conditions are 80 F db and 67 F wb in cooling and
70 F db in heating.
5. All performance data is based upon the lower voltage of dual volt-
age rated units. See Performance Correction Tables on page 21
for operating conditions other than those listed above.
6. ARI/ASHRAE/ISO 13256-1 (WLHP application) certified condi-
tions are 86 F EWT, 80.6 F db and 66.2 F wb in cooling and 68 F
EWT, 68 F db and 59 F wb in heating.
PRESSURE DROP (ft wg)
With
Without
Motorized
Motorized
Cv = 3.5
Valve
MOPD = 20 psi
2.3
2.8
4.3
5.3
7.2
8.9
2.3
2.8
4.3
5.3
7.2
8.9
2.3
2.8
4.3
5.3
7.2
8.9
2.3
2.8
4.3
5.3
7.2
8.9
2.3
2.8
4.3
5.3
7.2
8.9
4.3
5.3
2.3
2.8
4.3
5.3
7.2
8.9
2.3
2.8
4.3
5.3
7.2
8.9
2.3
2.8
4.3
5.3
7.2
8.9
With
Motorized
Cv = 2.5
MOPD = 50 psi
3.4
6.3
10.5
3.4
6.3
10.5
3.4
6.3
10.5
3.4
6.3
10.5
3.4
6.3
10.5
6.3
3.4
6.3
10.5
3.4
6.3
10.5
3.4
6.3
10.5
17