M:n redundancy switch
Table of Contents

Advertisement

RCS20 M:N Redundancy Switch
::= { radSNMP_Mod_Status 1 }
radMinorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
::= { radSNMP_Mod_Status 2 }
radCommonAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
::= { radSNMP_Mod_Status 3 }
radLatchedMajorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
::= { radSNMP_Mod_Status 4 }
radLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
::= { radSNMP_Mod_Status 5 }
radLatchedCommonAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
TM056 – Rev. 2.3
"Minor Alarm status:
A bit field. 0 = PASS, 1 = FAIL
Bit 1 = Terrestrial clock activity detect
Bit 2 = Tx data activity detect
Bit 3 = Interleaver FIFO empty error
Bit 5 = Loss of frame synchronization
"
"Common Alarm status:
A bit field. 0 = PASS, 1 = FAIL
Bit 0 = -12V alarm.
Bit 1 = +12V alarm.
Bit 2 = +5V alarm.
"
"Major Alarm latched status:
A bit field. 0 = PASS, 1 = FAIL
Bit 1 = Oversample Clock PLL Lock
Bit 2 = FPGA Configuration Error
Bit 3 = Synthesis Clock PLL Lock
Bit 4 = External Reference PLL Lock
"
"Minor Alarm latched status:
A bit field. 0 = PASS, 1 = FAIL
Bit 1 = Terrestrial clock activity detect
Bit 2 = Tx data activity detect
Bit 3 = Interleaver FIFO empty error
Bit 5 = Loss of frame synchronization
"