11.4.2 Connecting Requirement
The equipment's power supply 1 complies with IEC/EN 61000-3-12 provided that the short-circuit power S
greater than or equal to 868.69kW at the interface point between the user's supply and the public system. It is the
responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network
operator if necessary, that the equipment is connected only to a supply with a short-circuit power S
or equal to 868.69kW.
The equipment's power supply 1 shall be connected to a suitable supply network, having service current capacity
≥100A per phase. Please liaise with supply authority to ensure that the service current capacity at the interface
point is sufficient for the installation of the equipment.
The equipment's power supply 2 complies with IEC/EN 61000-3-12.
The equipment's power supply 2 shall be connected to a suitable supply network, with the following maximum
permissible system impedance Z
Please liaise with supply authority to ensure that the power supply 2 is connected only to a supply of that
impedance or less.
11.4.3 Wired Remote Control Instalation
Attached Accessories
No.
Name
(1)
Remote control
(2)
Remote control cable
Screw
(3)
(M4 machine pitched – 30mm)
Screw
(4)
(M4 self tapping – 14mm)
at the interface for models: 0.236Ω
max
Qty.
Diagram
1
1
3
3
35
Remark
Length (15 m)
Installing the remote control to an outlet box
(embedded cable)
Installing the remote control to the wall
(exposed cable)