8. MMI-Functions

8.1 Acoustics

Electro-Acoustic components are:

8.1.1 VIBRA

The VIBRA is activated and controlled from the EGOLD+
via the signal, VIBRA_ON. For this the VIBRA is connected to XG230 with BATT+.
GND is given by the shielding of the RF-Part. With a "H" of the VIBRA_ON signal
the transistor V230 is switched on. The signal
EGOLD+
(Miscellaneous M6).
due to a higher voltage required from the VIBRA in the beginning. The diode
is used to protect the circuit against over voltage and switching spikes.
timing of VIBRA_ON signal
V1.0
A35-A36-A40
a) VIBRA
b) Microphone
c) Loudspeaker
VIBRA_ON
This "second" VIBRA_ON is only used for ~40 to 65ms
Page 32 of 38
Company Confidential
(Miscellaneous E10)
appears also at the
V231
EGOLD+
Notes