Technibel CWX3B5XAB Technical Data & Service Manual page 10

Split system air conditioner
Table of Contents

Advertisement

CWX6B5XAB
Controller PCB
Part No.
Controls
Control circuit fuse
Jumper setting JP1..JP5
Remote Control Unit
Fan & Fan Motor
Type
Q'ty ....... Dia. and lenght
Fan motor model...Q'ty
No. Of poles...rpm (230 V, High)
Running Amps
Power input
Coil resistance (Ambient temp. 20 °C )
Safety devices
Run capacitor
Flap Motor
Type
Model
Rating
Coil resistance (Ambient temp. 25 °C )
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
Quantity of water
Type
Operating temp. Open
Close
mm
A
W
°C
°C
µF
VAC
Aluminium plate fin / Copper tube
mm
2
m
l
DATA SUBJECT TO CHANGE WITHOUT NOTICE
10
SAC ON-OFF IDU
Microprocessor
250 V - 3,15 A
2,54mm-5pcs
SAC W-REM
Centrifugal fan
1.... Ø 443
SFG6X-41D6P...1
6 ... 470
0,611
31,4
BRN-WHT: 170,3
WHT-VLT: 18,1
VLT-ORG: 43,2
ORG-YEL: 43,2
WHT-PNK: 83,5
YEL-BLK: 60,2
Internal thermal protector
130 ± 8
79 ± 15
4,5
450
Stepping motor
MP24Z2
DC 12 V
400 ± 7%
2
1,5
0,343
1,00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cwx6b5xabCwx8b5xabCwx10b5xabCwx5b5xab

Table of Contents