Southbend ECX-2S Owner's Manual

Convection steamer electric boiler
Hide thumbs Also See for ECX-2S:

Advertisement

CONVECTION STEAM
ELECTRIC BOIL
(Manual Section CS
OWNER'S MANUAL
INSTALLATION
USER'S GUIDE
SERVICE
PARTS
CONVECTION STEAMER
ELECTRIC BOILER
MODELS: ECX-2S
These instructions should be read thoroughly before attempting installation. Set up, installation
and Performance Check should be performed by a qualified service technician. The Manufacturer,
Southbend (1100 Old Honeycutt Rd., Fuquay-Varina, North Carolina 27526), informs you that
unless the installation instructions for the above described Southbend product are followed and
performed by a qualified service technician, (a person experienced in and knowledgeable
concerning the installation of commercial gas and/or electrical cooking equipment) then the terms
and conditions of the Manufacturer's Limited Warranty will be rendered void and no warranty of
any kind shall apply.
If the equipment has been changed, altered, modified or repaired by other than a qualified service
technician during or after the 12-month limited warranty period, then the manufacturer shall not be
liable for any incidental or consequential damages to any person or to any property which may
result from the use of the equipment thereafter. Some States do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation or exclusion thereto may
not apply to you.
In the event you have any question concerning the installation, use, care, or service of the
product, write Customer Service Department, Southbend Corporation, 1100 Old Honeycutt Rd.,
Fuquay-Varina, North Carolina 27526.
southbend
A MIDDLEBY COMPANY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECX-2S and is the answer not in the manual?

Questions and answers

Summary of Contents for Southbend ECX-2S

  • Page 1 Performance Check should be performed by a qualified service technician. The Manufacturer, Southbend (1100 Old Honeycutt Rd., Fuquay-Varina, North Carolina 27526), informs you that unless the installation instructions for the above described Southbend product are followed and performed by a qualified service technician, (a person experienced in and knowledgeable...
  • Page 2: Table Of Contents

    Congratulations! You have just purchased one of the finest pieces of heavy-duty, commercial cooking equipment on the market today. You will find that your new equipment, like all Southbend equipment has been designed and manufactured to some of the toughest standards in the industry - those of Southbend Corporation. Each piece of Southbend equipment has been carefully engineered and designs have been verified through laboratory tests and field installations in some of the more strenuous commercial cooking applications.
  • Page 3: Warranty

    Should any part thereof become defective as a result of normal use within the period and limits defined below, then at the option of Southbend such parts will be repaired or replaced by Southbend or its Authorized Service Agency. This warranty is...
  • Page 4: Dimensions

    DIMENSIONS & SERVICE CONNECTIONS STEAM-EX MODEL ECX-2 SECTION 1 FLOOR MOUNTED CONVECTION STEAMER FIG. 1 inches 5-1/2 4-1/2 193s 6-1/2 1-1/2 4-1/2 LEGEND Field Wiring Electrical Connection to be as specified on Electrical Rating Label which is according to Customer's Order. Appliance drain is 2"...
  • Page 5: Service Connections

    INSTALLATION & SERVICE CONNECTIONS STEAM-EX MODEL ECX-2 SECTION 1: FLOOR MOUNTED CONVECTION STEAMER INSTALLATION INSTRUCTIONS Ideally an Exhaust System should be provided directly above the Steam-Ex in order to exhaust steam and heat generated by the appliance. Set Steam-Ex in place and level appliance using spirit level. Ascertain that a floor drain (open gap) is convenient to the appliance drain.
  • Page 6 START UP & TESTING PROCEDURES STEAM-EX MODEL: ECX-2 SECTION 1: Floor Mounted Convection Steamer TESTING PROCEDURES Once the unit Is installed and proper service connections have been made, your Steam-Ex should be thoroughly tested before operation. If the appliance is equipped with a manual Blowdown Valve, close it. Open left cabinet door and turn ON Power Switch.
  • Page 7: Functioning Mode

    FUNCTIONING MODE STEAM-EX MODEL ECX-2 SECTION 2: FLOOR MOUNTED CONVECTION This Steam-Ex is intended for use in commercial establishments as an appliance utilizing steam in the pressureless mode for cooking a variety of food products. It is floor supported and consists of two sections, the Cabinet and the Cooker, both of which incorporate steel enclosures to contain live electrical parts.
  • Page 8 PERIODIC MAINTENANCE STEAM-EX MODEL ECX-2 FLOOR MOUNTED CONVECTION STEAMER SECTION 3: FIG. 2 SIDE VIEW...
  • Page 9 PERIODIC MAINTENANCE STEAM-EX MODEL ECX-2 SECTION 3: FLOOR MOUNTED CONVECTION STEAMER The Steam-Ex is made of two sections, the Cabinet and the Cooker. FIG. 2: The Cabinet is the lower section of the Steam-Ex and not only does it provide a base for the Cooker to be positioned at a proper working height but also provides the enclosure for the Boiler and Controls.
  • Page 10 PERIODIC MAINTENANCE STEAM-EX MODEL ECX-2 SECTION 3: FLOOR MOUNTED CONVECTION STEAMER Item J: Transformer. Primary Voltage as per Customer specifications. Secondary at 120V. Item K: Power Switch is fastened to the front face of the Generator Control Box and when switched ON will automatically begin the steam generating process in the Boiler.
  • Page 11 PERIODIC MAINTENANCE STEAM-EX MODEL ECX-2 SECTION 3: FLOOR MOUNTED CONVECTION STEAMER SIDE VIEW Item S: Safety Valve is a protective device set at 15 psi. Malfunction or improper setting of controls may allow the pressure to exceed 15 psi in the Boiler and will consequently set off this valve. ONCE A WEEK THIS VALVE SHOULD BE TRIPPED DURING OPERATION TO ASSURE THAT IT FUNCTIONS PROPERLY.
  • Page 12 PERIODIC MAINTENANCE STEAM-EX MODEL ECX-2 SECTION 3: FLOOR MOUNTED CONVECTION STEAMER FIG. 3...
  • Page 13 PERIODIC MAINTENANCE STEAM-EX MODEL ECX-2 SECTION 3: FLOOR MOUNTED CONVECTION STEAMER FIG. 3: The Cooker is the upper section of the steamer and is a two compartment appliance. Each compartment functions independently with its own controls. Item A: A Stainless Steel Screw on Gasket Plate immediately adjacent to each corner of Gasket allows adjustment of Gasket if necessary.
  • Page 14 OPERATING AND CLEANING INSTRUCTIONS STEAM-EX MODEL: ECX-2 FLOOR MOUNTED CONVECTION STEAMER SECTION 4: OPERATION If the appliance is equipped with a manual Blowdown Valve, close it. Open left cabinet door and turn ON Power Switch. Pilot light will come on (green) and water will begin to enter Boiler until required water level is reached (about 2 minutes).
  • Page 15 COOKING SCHEDULES STEAM-EX MODEL ECX-2 SECTION 5: FLOOR MOUNTED CONVECTION STEAMER THE FOLLOWING ITEMS MUST BE COOKED IN SOLID PANS: TIMER SETTING WEIGHT ITEM IN MINUTES PER PAN Eggs -Scrambled 10 - 12 8 Dozen Rice -Long grain (Cover with 4 cups water/lb) 2 Pounds Pasta (Place perforated pan inside solid pan, cover pasta with cold water)
  • Page 16 COOKING SCHEDULES STEAM-EX MODEL ECX-2 SECTION 5: FLOOR MOUNTED CONVECTION STEAMER PERFORATED PANS RECOMMENDED FOR FOLLOWING ITEMS: TIMER SETTING WEIGHT ITEM IN MINUTES PER PAN Clams -Frozen 10 - 12 3 Dozen -Fresh, cherrystone 3 Dozen King Crab (frozen) -Claws 2-1/2 Pounds -Legs 4-1/2 Pounds...
  • Page 17 COOKING SCHEDULES STEAM-EX MODEL ECX-2 SECTION 5: FLOOR MOUNTED CONVECTION STEAMER PERFORATED PANS RECOMMENDED FOR FOLLOWING ITEMS: - continued TIMER SETTING WEIGHT ITEM IN MINUTES PER PAN Brussel sprouts (frozen) 5 Pounds Cabbage (fresh) 1/6 cut 5 Pounds Carrots -Baby whole (frozen) 7 Pounds -Crinkle cut (frozen) 4 Pounds...
  • Page 18: Service Information

    SERVICE INFORMATION STEAM-EX MODEL ECX-2 SECTION 6: FLOOR MOUNTED CONVECTION STEAMER COOKER PROBLEMS DOOR GASKET LEAKS If Gasket is nicked, cut or at end of useful life it must be replaced. However, if leak occurs in one corner only and Gasket appears serviceable, then turn stainless steel screw on Gasket Plate immediately adjacent to leaking corner one half turn counterclockwise.
  • Page 19 SERVICE INFORMATION STEAM-EX MODEL ECX-2 SECTION 6: FLOOR MOUNTED CONVECTION STEAMER CABINET CONTROL PROBLEMS SAFETY RELIEF VALVE BLOWS AND RELEASES STEAM FREQUENTLY The Safety Relief Valve, set at 15 psi, is a protective device intended to prevent pressure from exceeding 15 psi in the Boiler.
  • Page 20 SERVICE INFORMATION STEAM-EX MODEL ECX-2 SECTION 6: FLOOR MOUNTED CONVECTION STEAMER CABINET CONTROL PROBLEMS (Continued) WATER IS NOT BEING SUPPLIED TO BOILER (Continued) coil inside and slide off from valve. Unscrew projecting tube from top of valve body and remove internal mechanism together with blade assembly.
  • Page 21 SERVICE INFORMATION STEAM-EX MODEL ECX-2 SECTION 6: FLOOR MOUNTED CONVECTION STEAMER CABINET CONTROL PROBLEMS (Continued) REMOVAL OF SCALANTS FROM BOILER (Continued) Remove 3/4" pipe Plug from end of Steam Take-off located on front head of Boiler next to handhole. Turn appliance Power Switch ON. Water will now enter and fill Boiler to required level and Heater Elements will come on.
  • Page 22 When ordering parts please supply the Model Number, Serial Number, Part Number, Description, plus Finish, and Electrical Characteristics, as applicable. For parts not listed consult a Southbend Authorized Parts Distributor or Southbend Authorized Service Agency. If necessary, please consult Southbend Escan Parts Department for assistance.
  • Page 23: Parts List

    PARTS LIST SECTION 7: CABINET FIG. 4 ITEM NO. PART NO. DESCRIPTION QUANTITY 8-1400 Cabinet Assembly (Galv. Back) 8-1410 Cabinet Assembly (Stainless Back) 8-1305 Side Panel 8-1308 Flanged Adjustable Foot (Rear) 5-FS64 Adjustable Foot Insert (Front) 5-MC02 Magnetic Door Catch 1-11C2 Magnetic Door Catch Screws 8-1303...
  • Page 24 PARTS LIST STEAM-EX MODEL ECX-2 SECTION 7: GENERATOR ASSEMBLY FIG. 5...
  • Page 25 PARTS LIST MODEL ECX-2 SECTION 7: GENERATOR ASSEMBLY FROM FIG. 5 ITEM NO. PART NUMBER DESCRIPTION QUANTITY 8-1600 Electric Boiler (Specify KW) 4-WC67 Low Hater Cut-Off 3-PG30 Boiler Pressure Gauge 3-WG20 Water Gauge Assembly 3-SRV3 Boiler Safety Valve 3-TST1 Thermostatic Steam Trap 8-1320 Exhaust Drain Assembly 8-1321...
  • Page 26 PARTS LIST MODEL ECX-2 SECTION 7: ELECTRIC BOILER ASSEMBLY FIG. 6...
  • Page 27 PARTS LIST MODEL ECX-2 SECTION 7: ELECTRIC BOILER ASSEMBLY FROM FIG. 6 Item No. Part Number Description Quantity 8-1415 Element (Specify KW & Voltage) 3 or 6* 8-1428 Element Fastening Nut (Specify KW) 6 or 12 8-1430 Element Enclosure Box (Specify KW) 2-75UO Fastening Nut 8-1410...
  • Page 28 PARTS LIST STEAM-EX MODEL ECX-2 SECTION 7: FLOOR MOUNTED CONVECTION STEAMER GENERATOR CONTROL FIG. 7 BOX COMPONENTS...
  • Page 29 PARTS LIST STEAM-EX MODEL ECX-2 SECTION 7: GENERATOR CONTROL BOX ASSEMBLY FROM FIG. 7 PART ITEM NO. DESCRIPTION QUANTITY NUMBER 3-PA26 Pressure Switch c/w 3-RD20 Transducer 4-FH03 Fuseholder 4-PL04 Pilot Light 4-S191 Power Switch 1-55C8 Pressure Switch Bolt 4-LQE7 Liquid Tite Elbow Assembly 4-LQE7 Liquid Tite Connector Assembly (to Element) 3-S252...
  • Page 30 PARTS LIST SECTION 7: COOKER ASSEMBLY FIG. 8...
  • Page 31 PARTS LIST STEAM-EX MODEL ECX-2 SECTION 7: COOKER ASSEMBLY Item No. Part Number Description Quantity 8-5101 Hinge Rod 8-5078 Bronze Bushing 8-5076 Door Assembly 8-5023 Perforated Trough Channel 8-5081 Compartment Drain Screen 8-5005 Digital Control Panel 8-5080 Pan Rack 1-34S4 Stainless Steel Panel Screws 8-5102 Enclosure Panel...
  • Page 32 PARTS LIST STEAM-EX MODEL ECX-2 SECTION 7: DOOR ASSEMBLY FIG. 9...
  • Page 33 PARTS LIST STEAM-EX MODEL ECX-2 SECTION 7: COMPARTMENT DOOR PARTS FROM FIG. 9 Item No. Part Number Description Quantity 8-5060 Door Panel 8-1101 Name Plate 8-5079 Bronze Bushing 8-5069 Latch Assembly Plate 1-CS77 Compression. Spring 8-5068 Locking Device 1-T658 Spring Tension Pin 8-5067 Latch Pin 8-5875...
  • Page 34 PARTS LIST STEAM-EX MODEL ECX-2 SECTION 7: FLOOR MOUNTED CONVECTION STEAMER COOKER CONTROL COMPONENTS FIG. 10...
  • Page 35 PARTS LIST STEAM-EX MODEL ECX-2 SECTION 7: COOKER CONTROL COMPONENTS FROM FIG. 10 Item No. Part Number Description Quantity 8-5061 Door Switch 4-T199 Transformer 8-5003 Printed Circuit Board 3-PA36 Pressure Switch 8-5002 Printed Circuit Board 4-TH04 Drain Thermostat (Water Cooling) 3-S263 Steam Solenoid Valve 3-P615...
  • Page 36 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 37: Wiring Diagrams

    WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 38 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 39 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 40 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 41 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 42 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 43 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 44 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 45 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 46 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 47 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 48 WIRING DIAGRAM SECTION 8: MODEL ECX-2...
  • Page 49 CONVECTION STEAMER ELECTRIC BOILER A product with the Southbend name incorporates the best in durability and low maintenance. We all recognize however, that replacement parts and occasional professional service may be necessary to extend the useful life of this unit. When service is needed, contact a Southbend Authorized Service Agency, or your dealer.

Table of Contents