C. MaxiScan Connexion System (MCS)

SCANNER port

RS-232 C
RS-422 / 485
C-2
RX
TX
CTS
RTS
RX-
TX-
RX+
TX+
1
2
3
4
9
10
11
12
CHASSIS
7-25 VDC
PWR GND
15-pin subD male connector
pin
1
receive data (RS-232 C) / RX- (RS-422 / 485)
2
transmit data (RS-232 C) / TX- (RS-422 / 485)
3
clear to send (RS-232 C) / RX+ (RS-422 / 485)
4
request to send (RS-232 C) / TX+ (RS-422 / 485)
5
positive synchronization input (SI+)
6
negative synchronization input (SI-)
7
positive synchronization output (SO+)
8
negative synchronization output (SO-)
9
not connected
10
power in (7 to 25 VDC 10 Watt unregulated)
11
power ground
12
shield
13
power ground
14
power in (7 to 25 VDC 10 Watt unregulated))
15
not connected
SI+
SI-
SO+
SO-
5
6
7
8
13
14
15
GND
7-25 VDC
function