John Bunn DigiO2 Operation Manual

John Bunn DigiO2 Operation Manual

Finger pulse oximeter
Hide thumbs Also See for DigiO2:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Operation Manual
Important: Do not operate the John Bunn DigiO
Finger
2
Pulse Oximeter without first reading and understanding
this manual! Save this manual for future use.
JB02007-INS-LAB-RevA07

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DigiO2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for John Bunn DigiO2

  • Page 1 Operation Manual Important: Do not operate the John Bunn DigiO Finger Pulse Oximeter without first reading and understanding this manual! Save this manual for future use. JB02007-INS-LAB-RevA07...
  • Page 2: Table Of Contents

    SPecIFIcAtIONS ......................16 LImIteD wARRANty ........................17 GF, Graham-Field, and John Bunn are registered trademarks of GF Health Products, Inc. Packaging, warranties, products, and specifications are subject to change without notice. GF Health Products, Inc. is not responsible for typographical errors.
  • Page 3: Introduction

    IntrODuCtIOn Dear User: Please read and understand all instructions before using the John Bunn DigiO Finger Pulse Oximeter, JB02007. Important Safety Guidelines - Please Read Before Use The safety statements presented in this chapter refer to the basic safety information...
  • Page 4 It must be used in conjunction with clinical signs and symptoms. It is intended as a measuring, not a treat- ment, device. John Bunn DigiO Finger Pulse Oximeter...
  • Page 5 When it is carried from a cold environment to a warm and/or humid environment, allow it to warm to room temperature before using it. DO NOT use sharp objects to press the front panel button. DO NOT immerse the oximeter in liquid. John Bunn DigiO Finger Pulse Oximeter...
  • Page 6: Intended Use

    Refer to the RePaIR aND MaINTeNaNCe/Cleaning and Disinfection section of this manual for instructions for cleaning and disinfection. Intended use The John Bunn DigiO Finger Pulse Oximeter, which combines a sensor and monitor into one device, is used to measure pulse oxygen saturation (SpO ) value, pulse rate value, and blood perfusion index (PI) or pulse strength in home or clinical settings.
  • Page 7: Overview

    OvervIew Appearance rubber cushion nameplate display battery cover display screen lanyard hole Figure 1 Figure 2 front view rear view John Bunn DigiO Finger Pulse Oximeter...
  • Page 8: Features

    Features The John Bunn DigiO Finger Pulse Oximeter provides a simple way to spot-check patients by combining the sensor and monitor into one integrated, compact, easy to use device with single-button operation. The oximeter can accurately measure pulse oxygen saturation (SpO ) value, pulse rate value, and blood perfusion index (PI) or pulse strength.
  • Page 9: Operation Instructions

    3. The device will power on automatically in two Figure 4 seconds, and start to display the software ver- operation sion number. John Bunn DigiO Finger Pulse Oximeter...
  • Page 10 180° Figure 7 Figure 8 and display as shown in Figure 8. d. Press the Display Key four times; the display screen will return to the original screen as shown in Figure 5. John Bunn DigiO Finger Pulse Oximeter...
  • Page 11 Display Key to suspend the alarm beep (see alarm table below). Alarm SpO Outside limit alarm: three Preset limit: ≤90% beeps Pulse Outside limit alarm: two beeps Preset limits: Low ≤50bpm, High ≥120bpm Rate John Bunn DigiO Finger Pulse Oximeter...
  • Page 12: Accessories (Included)

    Take out the batteries if the oximeter will not be used for a long period of time. Keep the device in a dry environment. Humidity may shorten the life of the device, or even damage it. John Bunn DigiO Finger Pulse Oximeter...
  • Page 13: Cleaning And Disinfection

    Caution: Do not sterilize with irradiation, steam, or ethylene oxide. Caution: Do not disinfect with high temperature or high pressure steam. Caution: Do not use the sensor if it is damaged. John Bunn DigiO Finger Pulse Oximeter...
  • Page 14: Troubleshooting

    3. Contact your Graham-Field distributor The indicator light 1. The device powers off 1. Normal suddenly turns off automatically when it gets no signal for eight seconds 2. The batteries are almost 2. Change the batteries drained John Bunn DigiO Finger Pulse Oximeter...
  • Page 15: Symbol Key

    Warning: See operation manual The pulse oxygen saturation Perfusion Index or Pulse Strength Pulse rate (beats per minute) Low battery voltage Serial number Do not treat this device as household waste— separate collection required John Bunn DigiO Finger Pulse Oximeter...
  • Page 16: Technical Specifications

    Values of SpO and Pulse Rate can be accurately measured by pulse man-made light oxygen simulator Dimensions (L x W x H) 2.59" x 1.42" x 1.3" (66 mm x 36 mm x 33 mm) John Bunn DigiO Finger Pulse Oximeter...
  • Page 17: Limited Warranty

    Electro-Magnetic Compatibility: Group I, Class B lIMIteD warranty GF Health Products, Inc. warrants the John Bunn DigiO Finger Pulse Oximeter, Model JB02007, for a period of one year for defects in workmanship and materials. During the warranty period, defective items will be repaired or replaced at manufacturer's option at no charge.
  • Page 18 USA, Corporate Headquarters: Graham-Field Health Products 2935 Northeast Parkway Atlanta, Georgia 30360 telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 www.grahamfield.com © 2007 GF Health Products, Inc. JB02007-INS-LAB-RevA07...
  • Page 19 Manual de Operación Importante: No debe operar el John Bunn DigiO Oxímetro sin leer y entender este manual! Guarde este manual para uso en el futuro. JB02007-INS-LAB-RevA07...
  • Page 20 .......................16 GARANtíA ..............................17 GF, Graham-Field y John Bunn son marcas registradas de GF Health Products, Inc. El embalaje, garantías, productos y specificaciones son sujetos a cambiar sin aviso. GF Health Products, Inc. no es responsable por errores tipográficos.
  • Page 21: Introducción

    De uSO Las declaraciones de seguridad presentado en este capitulo refieren a la información de seguridad básica que el operador del John Bunn DigiO Oxímetro de Pulso de uso Dactilar debe ponerle atención y seguirlo. Hay declaraciones de seguridad adicionales en otros capítulos o secciones, cuales pueden ser lo mismo o similar a lo siguiente o...
  • Page 22 Si los resultas son anormales, por favor de cambiar la posición del censor. el oxímetro es entendido solamente como un adjunto en la evaluación del paciente. Debe ser usado en conjunción con señales clínicas y síntomas. es entendido para un aparato de medir no tratamiento. John Bunn DigiO Oxímetro de Pulso...
  • Page 23 Cuando el aparato se cambia de un ambiente frió a uno caliente o húmedo, permite que se caliente a la temperatura del cuarto antes de usarlo. NO DeBe apretar el botón al frente con objetos afilados. John Bunn DigiO Oxímetro de Pulso...
  • Page 24: Uso Entendido

    Uso Entendido El John Bunn DigiO Oxímetro de Pulso de uso Dactilar, que combine un censor y moni- tor en un aparato entendido para medir el valor de la saturación del pulso de oxígeno (SpO ), el valor de frecuencia de pulso y índice de perfusión de sangre (PI) o fuerza de...
  • Page 25: Generalidades

    Apariencia cojín de goma placa de nombre botón de mostra protector de batería pantalla de mostra agujero del cordón Figura 1 Figura 2 vista frontal vista de atrás John Bunn DigiO Oxímetro de Pulso...
  • Page 26: Características

    Oxímetro de Pulso de uso Dactilar provee un método simple para chequear a los pacientes combinando un censor y monitor en un aparato integrado y com- pacto que es fácil de usar y que tiene operación de un botón. El John Bunn DigiO Oxímetro de Pulso de uso Dactilar puede ser usado para medir el valor de la saturación del pulso...
  • Page 27: Instrucciones De Operación

    2. Mete su dedo en el cojín de goma (asegurase que su dedo está en la posición correcta). 3. El aparato se aprenderá automáticamente en 2 segundos, y le enseñará el número de la versión de Figura 4 software. operación John Bunn DigiO Oxímetro de Pulso...
  • Page 28 Apreté el Botón de Mostrar tres veces, la pantalla (que se ve como en la Figura 8) se volteará 180° grados. d. Apreté el Botón de Mostrar cuatro veces, la pantalla se volviera a la pantalla original como en la Figura 5. John Bunn DigiO Oxímetro de Pulso...
  • Page 29 Botón de Mostrar para suspender el sueno del alarme (vea la tabla de alarmes). Limites de Alarme de SpO Limite inferior (3 Alarme presente: <90% los alarmes pitidos) presentes Alarme de frecuen- Limite alta (2 pitidos) Alarmes presente: Bajo <50bpm, Alto >120bpm cia de pulso John Bunn DigiO Oxímetro de Pulso...
  • Page 30: Accesorios (Incluidos)

    Repito si es necesario. Saque las baterías del oxímetro si no va usar el aparato por un periodo de tiempo largo. Guarde el aparato en un ambiente seco. Humedad puede reducir o dañar la vida del aparato. John Bunn DigiO Oxímetro de Pulso...
  • Page 31: Limpiar Y Desinfectar

    Caución: No debe esterilizar por vapor irradiación óxido de etileno. Caución: No debe desinfectar con temperatura alto o vapor de alta presión. Caución: No debe usar el censor si está dañado. John Bunn DigiO Oxímetro de Pulso...
  • Page 32: Detectando Problemas

    Graham-Field La luz del indicador se 1. El aparato se apaga automáticamente 1. Normal apaga de repente cuando no hay señal por ocho segundos 2. Las baterías se han gastado 2. Cambie las baterías John Bunn DigiO Oxímetro de Pulso...
  • Page 33: Símbolos

    La saturación de oxígeno de pulso Índice de Perfusión/Intensidad de Pulso Frecuencia de Pulso (latos por minuto) Voltaje baja de las baterías Numero Serial No debe tratar este aparato como residuos de domésticos—colección separado es necesario John Bunn DigiO Oxímetro de Pulso...
  • Page 34: Especificaciones Técnicas

    Valores de SpO y Frecuencia de Pulso pueden ser medidos con artificial presión por un simulador de oxígeno de pulso Dimensiones (L x W x H) 2.59" x 1.42" x 1.3" (66mm x 36mm x 33mm) John Bunn DigiO Oxímetro de Pulso...
  • Page 35: Garantía

    Equipo ordinario sin protección contra inmersión de agua Compatibilidad Electromagnético: Grupo I, Clase B garantÍa GF Health Products, Inc. garantía el John Bunn DigiO Oxímetro de Pulso, Modelo JB02007 por un periodo de un año por defectos en la factura y materiales. Durante el periodo de garantía, artículos defectivos pueden ser arreglados y cambiadas por el...
  • Page 36 USA, Jefaturas Corporativas : Graham-Field Health Products 2935 Northeast Parkway Atlanta, Georgia 30360 tel: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 www.grahamfield.com © 2007 GF Health Products, Inc. JB02007-INS-LAB-RevA07...