L300/L500 - Dometic L 100 Service Instruction

Ventilation systems for caravan and motorhome
Hide thumbs Also See for L 100:
Table of Contents

Advertisement

8.2

L300/L500

Fig. 1
L500
L500
Fig. 2
Installation steps
1. Cut out a rectangle (L300:width 490mm, height 249mm, L500:width 451mm,
height 341mm) in the external wall and install the frame (1) with screws.
2. Position the ventilation grid (2) into the frame (1) and fasten it with the
locking screws (3).
Please note, that this ventilation grid does not have the parts for the
exhaust conduction.
The upper ventilation grid should be positioned as high as possible above
condenser (A).
The lower ventilation grid should be flush with the floor of the vehicle.
Minimum ventilation height (H) = ca. 1400mm − 1500mm
3
2
A
H
10-20mm
B
1
A =
Condenser
B
B =
Stopper strip with profiled joint
H =
Ventilation height
14