Specifications - Flin Energy FlinSlim 1 kVA User Manual

Solar pure sine wave inverter/ups
Table of Contents

Advertisement

SPECIFICATIONS

Table 1 Line Mode Specifications
INVERTER MODEL
Input Voltage Waveform
Nominal Input Voltage
Low Loss Voltage
Low Loss Return Voltage
High Loss Voltage
High Loss Return Voltage
Max AC Input Voltage
Nominal Input Frequency
Low Loss Frequency
Low Loss Return Frequency
High Loss Frequency
High Loss Return Frequency
Output Short Circuit Protection
Efficiency (Line Mode)
Transfer Time
Output power derating:
When AC input voltage drops to 170V,
the output power will be derated.
1KVA
2KVA
Sinusoidal (utility or generator)
170Vac± 7V (UPS);
90Vac± 7V (Appliances)
180Vac± 7V (UPS);
100Vac± 7V (Appliances)
50Hz / 60Hz (Auto detection)
Circuit Breaker
>95% ( Rated R load, battery full charged )
10ms typical (UPS);
20ms typical (Appliances)
Output Power
Rated Power
50% Power
90V
27
FlinSlim Solar Inverter
3KVA
4KVA
230Vac
280Vac± 7V
270Vac± 7V
300Vac
40± 1Hz
42± 1Hz
65± 1Hz
63± 1Hz
170V
280V
5KVA
Input Voltage

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents