Note: When the unit runs 0.5h, the time cumulates one time, and no cumulation if runs less than 0.5h. The corresponding
indicator lamp blinks to remind customer clean or replace it when the total cumulate time reaches. Before the cumulate
time haven't been cleared, the indicator blinks if re-energized. If both cumulate time of clean and replace do not reach,
they are clearance after resetting (used for factory-zero clearing), if one cumulate time reaches, only clear it after
resetting, the other continues to run; if both of them reach, clear them after resetting.
4 Function of remote control button
◆ ON/OFF: After the unit is first energized, press ON/OFF when the unit is off, it will run with auto mode, if turn on the
unit again it will run with the previous mode, the unit is off if pressing ON/OFF when the unit is on.
◆ Child Lock: Press it for 2S, the unit runs under this mode; it will be cancelled for 2 ways: lock function key with remote
controller (press for 2S) or the unit is power-fail.
◆ Six mode keys: There are below modes: auto, turbo, sleep, anion, clear off-flavor. The button is valid when the unit is
on.
a. If the current modes are auto, sleep and turbo, it will shift to the default status of this mode if pressing anion and anti
off-flavor. If the current modes are anion and anti off-flavor, press the mode key which the same as the current mode, the
buzzer gives out beep and no action for controller.
b. If the current mode is DUST:
Enter anion mode if press anion button, and default the status operation if press anion mode.
Enter clear off-flavor mode if press off-flavor button, and default the status operation if press clear off-flavor mode.
There is no change if press dedust button.
c. If the current mode is anion: Enter clear off-flavor mode if press off-flavor button, and default the status operation if
press clear off-flavor mode. There is no change if press anion/static dedust button.
d. If the current mode is clear off-flavor: Enter anion mode if press anion button, and default the status operation if press
anion mode. There is no change if press clear off-flavor /static dedust button.
◆ Timer Key: The unit will choose circularly by timer 1h->2h->4h->cancel if press this button.
Press timer if the unit is off, that means set timer on; press timer if the unit is on, that means set timer off. Eg: set the
current timer to turn off the unit 1h later, then repress it is to turn off the unit 2h later, and then repress is to turn off the
unit 4h later, last press it is cancel it. Then press it is to turn off the unit 1h later, cycle like this.
Note: If the current setting timer is 1h and does not reach, presses TIMER, the timer time will update to2h, and restart to
time regarding 2h.
If the unit is on and is set timer time off already, receiving the signal to turn off the unit, the unit is off and clears timer
information.
If the unit is off and is set timer time on already, receiving the signal to turn on the unit, the unit is on and clears timer
information.
◆ Fan Key: It cycles by quiet->low speed->high speed (It is invalid with stand-by, auto, sleep and turbo mode). The fan
speed runs with initial fan speed of each model when shift mode by remote control.
◆ Setting Key: The brightness of indicator lamp will be adjusted per press, the dust induction lamp and off-flavor
induction lamp will display circularly by bright->dark->go out, and other lamps will display circularly by
bright->dark->dark->bright.