FältCom ECII SE Manual And Installation Instructions

FältCom ECII SE Manual And Installation Instructions

Fältcom ecii se manual and installation instructions
Table of Contents

Advertisement

FältCom ECII SE
Manual and installation instructions
Version:
5.2
Updated:
2006-10-25
Manual FältCom ECII SE Eng
Page 1 of 36

Advertisement

Table of Contents
loading

Summary of Contents for FältCom ECII SE

  • Page 1 FältCom ECII SE Manual and installation instructions Version: Updated: 2006-10-25 Manual FältCom ECII SE Eng Page 1 of 36...
  • Page 2: Table Of Contents

    More available functions ..................6 7.2.1 Change of time delay for alarm button..............6 7.2.2 Connection via telephone exchange..............6 7.2.3 Activation of automatic test alarm................ 6 7.2.4 Answering function....................6 7.2.5 Alarm mode......................6 Manual FältCom ECII SE Eng Page 2 of 36...
  • Page 3 Whistling sound from loudspeaker (at alarm sequence).......... 6 Disturbance during voice communication ..............6 Technical support ..................... 6 TECHNICAL DATA ......................6 PROGRAMMING KEY MAP .................... 6 CONTACT INFORMATION ....................6 Manual FältCom ECII SE Eng Page 3 of 36...
  • Page 4: Notes

    We would like to thank you for placing your confidence in Fält Communications AB and are convinced about the choice of one of our security products will fulfill your expectations. In order to operate this FältCom ECII SE correctly we would ask you to read this manual carefully.
  • Page 5: Updates

    The customer can ask for a quotation for repair of product not covered by warranty. Manual FältCom ECII SE Eng Page 5 of 36...
  • Page 6: Service Form

    3.4.1 Service form Manual FältCom ECII SE Eng Page 6 of 36...
  • Page 7 Manual FältCom ECII SE Eng Page 7 of 36...
  • Page 8: General

    FältCom ECII SE should only be used in the context for which it is intended. All other form of usage will be considered as being solely the users own risk. Only qualified persons are permitted to install, program and start-up this product.
  • Page 9: Product Description

    The company is not forced to immediately update reference manuals. Product description The FältCom ECII SE is alarm equipment for the PSTN network with built in duplex speech communication designed for installation in lifts. The FältCom ECII SE is a dialing alarm transmission unit with built-in voice communication function, intended for installation in passenger lifts.
  • Page 10 For the separate suspension cable, there is a special mounting kit, which includes the necessary mounting parts. The FältCom ECII SE consumes very little power and can be supplied by the voltage from the telephone line. Separate power supply is only required if several lift phones are connected to the same telephone line or if the line voltage is below 32 VDC.
  • Page 11: Multiple Lift Phone Connection

    When the line becomes free, the alarm call will be connected automatically. Installation of two or more FältCom ECII SE on the same telephone line requires a separate power supply to the lift phones. The lift phone outlet marked DC is then connected to the existing emergency power supply of the lift via a special DC/DC converter.
  • Page 12: Programming And Testing

    It is also possible to remotely program the lift phone with a special Windows program and a modem. Contact your local distributor for more information. The FältCom ECII SE is capable of calling 6 alarm receivers or standard telephones with tone selection.
  • Page 13: Frame Mounting

    Note that the alarm button in the lift cage is normally double-breaking, i.e. made for two separate connections, one of them usually connected to a local bell and the other one used Manual FältCom ECII SE Eng Page 13 of 36...
  • Page 14: Closing Alarm Button Function

    Please note that there is a special version of the FältCom ECII SE with an integrated alarm button which can be used if there is no suitable alarm button available in the lift. That version has a double breaking alarm button where one part (NC) is used for the lift phone and the other part (NO) can be used for the alarm bell.
  • Page 15: Connection With Separate Suspension Cable

    Connect the two central wires in the enclosed modular connector to the suspension cable wire, and connect the modular connector to the telephone jack in the engine room. Mark the connection so that it will not be removed by mistake. Manual FältCom ECII SE Eng Page 15 of 36...
  • Page 16: Connection Via Existing Cable

    When connecting two or more lift phones on the same telephone line, each phone shall be programmed for detection of occupied line: To deactivate this function, press: Manual FältCom ECII SE Eng Page 16 of 36...
  • Page 17: Connection To Loop Amplifier

    To enable passengers with impaired hearing to communicate with alarm centre there is a possibility to connect a loop amplifier. Contact your local distributor for information about approved loop amplifier to be used with FältCom ECII SE. Connect the output marked “LOOP AMP” to the loop amplifier. The loop amplifier must work during power failure.
  • Page 18: Programming

    For practical and ergonomically reasons it is recommended that all programming is done at (e.g. at a desk) before the FältCom ECII SE is mounted in the lift. All programming remains in the lift phone also after it is disconnected from the telephone line.
  • Page 19: Standard Functions

    Should the FältCom ECII SE be connected to a closing alarm button or no alarm button at all, it is sufficient to press only the key to enter programming mode. Note that the time delay for activation of programming mode is the same as the selected time delay for the alarm button.
  • Page 20: Closing Alarm Button Function

    1. Check that the alarm reaches alarm receiver 2 by pressing (in programming mode): If there are more alarm receivers, test them by substituting in the sequence above by etc. Manual FältCom ECII SE Eng Page 20 of 36...
  • Page 21: More Available Functions

    FältCom ECII SE handles this by having the alarm number start with a zero and an asterisk. The asterisk after the zero makes the lift phone wait two seconds for a dialing tone. The waiting time is increased if you press two or more times.
  • Page 22: Answering Function

    Press the following sequence to activate the function: With two or more FältCom ECII SE on the same telephone line, one of them is programmed as the master with ID number ”1”. The others are coded with their individual number (2-6) by replacing the digit with the corresponding digit.
  • Page 23: Alarm Mode

    7.2.6 Alarm mode If the alarm mode function is active the FältCom ECII SE can only receive incoming calls for 6 hours after the alarm was called out. After this time the lift phone will be closed for incoming calls until a new alarm is triggered. To activate the alarm mode the following conditions must be fulfilled: •...
  • Page 24: Busy Line Function

    Where “1” is the identity of the lift from 1 - 6. Alarm mode function is disabled with: The active alarm mode is automatically disconnected after 6 hours but will be extended with 6 hours if a new speech connecting alarm is made or if a call is made to FältCom ECII SE during this interval.
  • Page 25: Simplified Acknowledge

    A second function must be activated which learns the FältCom ECII SE how a correct busy tone sounds like. Since this differs between countries one has to adapt the programming depending on country.
  • Page 26 Normally a telephone line shifts polarity when the telephone is lifted and at hang up and the lift phone FältCom ECII SE can detect this. Because of this the lift phone can disconnect a call faster when the function Disconnection of acknowledgement is activated and the trapped passenger does not need to listen to an occupied tone in the lift phone speaker until the call is terminated after maximum 3 minutes.
  • Page 27: Change Of Alarm Flashing Sequence

    When the function is active, the FältCom ECII SE will replace the normal beep sequence with a start beep, followed by sequence of beeps with another frequency. The number of beeps in the sequence is controlled by the first digit in the alarm code. If the alarm code is 345678 the lift phone will start with a beep and the play out 3 beeps with a different frequency.
  • Page 28: Info Alarm

    To return to the CPC protocol the following sequence is programmed: 7.2.17 Dial tone detection FältCom ECII SE has a function which makes it possible to first wait for dial tone before the call out sequence starts. Default this function is deactivated but can be activated with: The function is deactivated with the following programming sequence: Manual FältCom ECII SE Eng...
  • Page 29: Alarm Call

    Therefore, note that all alarm receivers should practice the alarm handling procedure. If the alarm receiver has not answered within 60 seconds the FältCom ECII SE will automatically switch to the next alarm number. The lift phone waits 60 seconds before next alarm number is dialed.
  • Page 30: Speech Exchange

    If answering function is activated, or if alarm mode function is programmed, and FältCom ECII SE is in active alarm mode, it is possible make a call to FältCom ECII SE from a tone dialing phone or a mobile according to the following: Dial the number to the lift phone.
  • Page 31: Troubleshooting

    Lift phone calls up automatically at power on The lift phone’s alarm button has closing function but the FältCom ECII SE is set for an alarm button with breaking function (or vice versa). See Programming section.
  • Page 32: Technical Data

    22 VDC. If also an external power supply is connected together with the jumper the lift phone will work down to 12 VDC. When the jumper is mounted FältCom ECII SE is not allowed to be connected to the public switched telephone network (PSTN). Supply voltage:...
  • Page 33: Programming Key Map

    If no button is pushed during a time lapse of 30 sec. programming mode is automatically deactivated. Below follows an overview of all programmable functions in FältCom ECII SE. In the column to the right are the possible normal values marked with “X” or shown with the actual value.
  • Page 34 Deactivation of battery alarm receiver Test of battery alarm < Code > Alarm code to battery alarm receiver. Max 10 digits Activation of simple phone acknowledge Reset of normal acknowledge sequence Manual FältCom ECII SE Eng Page 34 of 36...
  • Page 35 Deactivation of busy line detection Activation of automatic disconnection Deactivation of automatic disconnection Activation of info alarm Deactivation of info alarm Reset all settings to factory mode Deactivation of programming mode Manual FältCom ECII SE Eng Page 35 of 36...
  • Page 36: Contact Information

    Homepage: www.faltcom.com Service address: Fält Communications AB c/o BL Elektronik AB Furuhedsvägen 1 SE-952 31 KALIX, Sweden Phone: + 46 (0)923 667 20 Fax: + 46 (0)923 125 40 Homepage: www.bl-elektronik.com Manual FältCom ECII SE Eng Page 36 of 36...