Before installing your SunPhase heater, the following should be reviewed.
1. The gas inlet supply pressure cannot exceed 5kPa. Manifold pressure
for Natural gas is 1.0kPa and for LPG is 2.7 kPa.
2. Do not locate the gas supply line or the electrical supply near the heat
outlet of the heater.
3. The heater must be installed in a location where it is readily accessible
for service and have no restrictions of air flow.
4. When installed outdoors this heater must be in a covered area protected
from rain water.
5. For all installations this appliance must be a minimum of 1.8m above
floor level.
Please note:
 If installed outdoors this appliance shall only be used in an above ground
open air situation with natural ventilation, without stagnant areas, where
gas leakage and products of combustion are rapidly dispersed by wind
and natural convection.
 This appliance may be installed indoors in commercial premises. The
minimum room volume is 125 M³ (Model SunPhase 25E LP/NG) and 80
M³ (Model SunPhase 16E LP/NG). If this appliance is to be installed
indoors check with your local gas authority to determine the minimum
height of installation.
 This appliance must only be used in a well ventilated area.
 In winds exceeding 10KM/h this heater may go to a safe shut down.
 The manufacturer does not warrant the operation of the heater if installed
in areas with wind speeds in excess of 10km/hr, without some form of
wind protection such as drop-down plastic blinds