Page 2
SAFETY INSTRUCTIONS Please read and follow these safety guidelines to safeguard yourself and others: • GSM control system ESIM252 (later referred to as “the system” or “ the device”) contains a built-in radio transceiver operating in GSM 850/900/1800/1900 MHz bands.
21. TECHNICAL SUPPORT ................................48 21.1. Troubleshooting ......................................48 21.2. Restoring Default Parameters ..................................48 21.3. Updating the Firmware via USB Cable ................................ 48 21.4. Updating the Firmware via GPRS Connection Remotely ......................... 49 22. RELATED PRODUCTS................................50 ESIM252 User Manual v2.1...
Page 4
The buyer agrees that the system will reduce the risk of fire, theft, burglary or other danger but that it does not guarantee against the oc- currence of such events. “ELDES UAB” will not take any responsibility for the loss of personal effects, property or revenue whilst using the system.
1. GENERAL INFORMATION ESIM252 is a micro-controller based device intended to receive alarm/restore events by SMS text message or phone call and control an electrical appliance via the GSM network. Examples of using the system: • Access control. • Gate control of private houses.
Main Unit Functionality Connector Functionality GSM/GPRS antenna SMA type connector AC/DC Power supply terminals Mini USB port RELAY1 ESIM252 output C1 terminal SIM CARD SIM card slot / holder RELAY2 ESIM252 output C2 terminal GSM MODEM GSM network 850/900/1800/1900 MHz...
3. Disable the PIN code request of the SIM card by inserting it into a mobile phone and following the proper menu steps. 4. Once the PIN code is disabled, insert the SIM card into the SIM card slot / holder of ESIM252 system.
4. GENERAL OPERATIONAL DESCRIPTION GSM control system ESIM252 uses the GSM network for event transmission by SMS text message. When one of the 5 available listed num- bers dials the system, it answers the call and the user can listen to a pre-recorded audio message and hear what is going on in the premises once the audio message is over.
SMS password – 4-digit password used for system configuration and control from user phone number by SMS text messages and logging in to ELDES Configuration Tool software. By default, SMS password is 0000, which MUST be changed! SMS text message content:...
Value: ssss – 4-digit SMS password; u – user phone number slot, range – [1... 5]; ttteeellnnu- umm – up to 15 digits administrator phone number. Example: 1111_NR1:441709xxxxxxx Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: View user phone...
Value: ssss – 4-digit SMS password. number Example: 1111_STR:ON Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Disable system ssss_STR:OFF control from any Value: ssss –...
– [01... 31]; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59]. Example: 1111_2014.03.16_14:33 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool NOTE: When the system is connected to the monitoring station via GPRS network connection (see 19. MONITORING STATION), the date and time will be automatically synchronized with the monitoring station or Smart Security server upon the system startup.
Value: ssss – 4-digit SMS password. Example: 1111_INFO Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool 10.1. Pulse Counter The system comes equipped with input pulse counter feature. The feature determines the number of input violation events, known as pulses, that result in input alarm SMS text message delivery and/or phone call to the listed user phone number once the number of the set up pulses is achieved.
Page 15
Enable input Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]. Example: 1111_Z5:ON Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: ssss_STATUS View input status Value: ssss –...
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number slot, range – [1... 5]. Example: 1111_SMSEXTRA:Z4:SC4 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Enable input alarm...
Page 17
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number slot, range – [1... 5]. Example: 1111_SMSEXTRA:Z1:SE5 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Disable input restore...
Page 18
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number slot, range – [1... 5]. Example: 1111_SMSEXTRA:Z2:CC4 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Enable input alarm...
Value: ssss – 4-digit SMS password. users simultaneously Example: 1111_SMSALL:ON Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Disable alarm/restore ssss_SMSALL:OFF SMS text message delivery to all listed Value: ssss –...
13. OUTPUTS ESIM252 comes equipped with 2 built-in outputs for electrical appliance or non-GSM alarm panel’s zone connection. Normally, the output can be used to open/close garage doors, activate lights, heating, watering as well as a key-switch for non-GSM alarm system arming/dis- arming.
Value: ssss – 4-digit SMS password. Example: 1111_STATUS Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool ATTENTION: Space, colon, semi-colon characters, parameter names and/or values, such as PSW, STATUS, ON, OFF etc. are NOT allowed in output names.
Page 22
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number slot, range – [1... 5]. Example: 1111_SMSEXTRA:COC1:MS20 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Set output control ssss_SMSEXTRA:COCo:MSuThr.mn.sc...
Page 23
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone call back number slot, range – [1... 5]. Example: 1111_SMSEXTRA:COC1:CS3 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Disable output control ssss_SMSEXTRA:COCo:CCu via call confirmation by Value: ssss –...
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; out-name – up to 11 as ON characters output name. Example: 1111_Lamp:ON Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Turn OFF output/Set ssss_Co:OFF...
Page 25
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]. confirmation by SMS Example: 1111_SMSEXTRA:OCS2:SB0 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Enable output control...
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; cd – call back dura- tion, range – [0... 60] seconds. Example: 1111_SMSEXTRA:OCS1:CT020 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool 13.4. Automatic Output Control ATTENTION: System date and time must be set, otherwise the system will NOT be able to control the output (-s) automatically.
Page 27
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone control confirmation number slot, range – [1... 5]. acceptance Example: 1111_SMSEXTRA:OCTE1:UC2 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Disable output control ssss_SMSEXTRA:OCTEo:SS0 confirmation by SMS Value: ssss –...
Page 28
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]. back for scheduler start Example: 1111_SMSEXTRA:OCTE1:CS0 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Enable output control...
Value: ssss – 4-digit SMS password; fff – frequency, range – [00... 99] days; it – time, range – [01... 23]. Example: 1111_INFO:3.15 Config This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool SMS text message content: Disable periodic...
By default, System Startup notification is enable. To disable/enable it , please refer to the following configuration method. Config Manage System This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool Startup notification 15.1. SMSC (Short Message Service Center) Phone Number An SMS center (SMSC) is a GSM network element, which routes SMS text messages to the destination recipient and stores the SMS text message if the recipient is unavailable.
By default, event log is disabled. To enable/disable this feature, please refer to the following configuration methods. Config Enable/disable This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool event log To export the event log to .log file or clear it, please refer to the following configuration methods.
17. REMOTE LISTENING ESIM252 may be equipped with a microphone that allows the user to listen on his mobile phone to what is happening in the area surround- ing the microphone. Remote listening feature can operate under the following conditions: •...
GSM operator according to the cell phone service plan. Config Enable/disable This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool MS mode Account is a 4-digit number (By default – 9999) required to identify the alarm system unit by the monitoring station.
Page 34
Config connection This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool If all attempts by all set connections are unsuccessful, the system will wait until the delay time (By default – 600 seconds) expires and will attempt to transmit data to the monitoring station again starting with the primary connection.
Page 35
Value: ssss – 4-digit SMS password; ptc – protocol, range – [TCP... UDP]. Example: 1111_SETGPRS:PROTOCOL:UDP Config Set Set data format as This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool EGR100 or Kronos Config Set DNS1/ DNS2 This operation may be carried out from the PC using the ELDES Configuration Tool software.
Page 36
Set/delete Config monitoring station This operation may be carried out from the PC using the ELDES Configuration Tool software. Tool phone number By default, if the initial attempt to transmit data to the monitoring station’s Tel Number 1 via Voice Calls method is unsuccessful, the system will make up to 4 additional attempts.
ON, while when the system is disarmed in enterprise B, PGM2 would result in being turned OFF. b) PGM1 has to be connected to ESIM252 input Z1, while PGM2 must be connected to ESIM252 input Z2. (PGM2 must be of “high level”)
Page 38
First of all alarm system unit must be configured in the way so that triggering PIR sensor would result in PGM3 being turned ON. b) PGM3 has to be connected to ESIM252 input Z3 c) The following SMS text message must be sent to ESIM252 system: ssss_SMSEXTRA:Z3:SC1245,CC1245,SE3 SC1245 = alarm SMS text message sending to users NO1, NO2, NO4 and NO5 is disabled after Z3 is violated.
Page 39
First of all alarm system unit must be configured in the way so that triggering a PIR sensor of enterprise A would result in PGM4 being turned ON. b) PGM4 has to be connected to ESIM252 input Z4 c) The following SMS text messages must be sent to ESIM252 system: ssss_SMSALL:ON SMSALL = enables mandatory SMS text message delivery feature for all users.
Page 40
First of all alarm system unit must be configured in the way so that triggering a PIR sensor of enterprise A would result in PGM5 being turned ON. b) PGM has to be connected to ESIM252 input Z5 C) The following SMS text messages must be sent to ESIM252 system: ssss_SMSALL:ON SMSALL = enables mandatory SMS text message delivery feature for all users.
20.2. Using in a Private House The user wants to connect ESIM252 system to the PGM outputs of an existing alarm system. House area is accessible through electrically controlled gates. There are 5 users in total. NO1 is the housekeeper, NO2 is a neighbour, while NO3-NO5 are the family members.
Page 42
Confirmation call feature must be enabled for user NO5 and it is necessary to set the duration parameters for that call. Also, confirmation by SMS text messages have to be enabled for user NO3. a) First of all ESIM252 output has to be connected to the gate automation equipment. b) The following SMS text message must be sent to ESIM252 system: ssss_SMSEXTRA:COC:CE1345,CS5,CT513,SS3,MS10,MS30,MS40,MS50,MS1T0.0.1,MS3T0.0.1,MS4T0.0.1,MS5T0.0.1...
ON, the confirmation call will last for 3 seconds, while when the output has been turned OFF, the confirmation call will last for 10 seconds a) First of all ESIM252 output C1 has to be connected to the heating system control unit. b) The following SMS text message must be sent to ESIM252 system: ssss_SMSEXTRA:COC:CE1,CS1,CT113,CT1010,MS12 CE1 = C1 output control via call is enabled for users NO1.
Page 44
NO1 and NO2. Mandatory SMS delivery to all users must be enabled. a) First of all a flood sensor has to be connected to ESIM252 input Z1. b) The following configuration SMS text messages must be sent to ESIM252 system: ssss_SMSALL:ON SMSALL = enables mandatory SMS text message delivery feature for all users.
By default, SMS text message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS text message, therefore it is necessary to remove users NO2 and NO3 and disable alarm calls for all users. It is also necessary to invert ESIM252 input from NO to NC mode so that alarm is given only if the signal disappears.
Page 46
ESIM252 input Z3 and set the number of expected pulses. a) First of all signal wires (fault output) indicating the pump triggering has to be connected to ESIM252 input Z3. b) The following SMS text message must be sent to ESIM252 system: ssss_SMSEXTRA:Z3:SC13,CC123,IE1,IC10 SC13 = alarm SMS text message sending is disabled for users NO1, NO3 if Z3 input is violated.
Page 47
ON for 2 seconds; once this this period expires, the output will return to the previous state. a) First of all ESIM252 output has to be connected to the automatic system control unit.
For product warranty repair service please , contact your local retail store where this product was purchased. If your problem could not be fixed by the self-guide above, please contact your local distributor. More up to date information about your device and other products can be found at the manufacturer’s website www.eldes.lt 21.2. Restoring Default Parameters 1.
Comma and underscore character is NOT allowed to use in user name, password and firmware file name. ATTENTION: “ELDES UAB” does not run a FTP server and does not host the firmware files online. Please, contact your local distributor to request the latest firmware file.