INSTALLER
MAKING CONNECTIONS
Controller Link In and Link Out
Controller Link In/Out
The Controller Link In and Link Out can be used
to connect up to six CAA66 controllers. The con-
nection is made using a CAT-5 patch cable from
the Link Out of the master CAA66 and into the
Link In of the next controller. Along with data sig-
nals, the Controller Link In and Link Out jack
passes the six source IR signals. The CAT-5
patch cable should not exceed 18 inches in
length to avoid potential cross-talk between the
source-specific IR repeating signal lines.
26
Note: If two or more CAA66 controllers will be
connected using the Controller Link In and Link
Out ports, each controller must have a unique
Controller ID prior to being connected through
the Link In and Out ports. The Controller ID
assignment must be performed during the
Controller Setup section of the Installation menu.