✱ 65
OPEN REPORT CODE
✱ 66
ARM AWAY/STAY RPT CODE
✱ 67
RF XMTR LOW BAT REPORT CODE
✱ 68
CANCEL REPORT CODE
RESTORE REPORT CODES ( ✱ 70 – ✱ 76)
✱ 70
ALARM RESTORE RPT CODE
✱ 71
TROUBLE RESTORE RPT CODE
✱ 72
BYPASS RESTORE RPT CODE
✱ 73
AC RESTORE RPT CODE
✱ 74
LOW BAT RESTORE RPT CODE
✱ 75
RF XMTR LO BAT RST RPT CODE
✱ 76
TEST RESTORE RPT CODE
OUTPUT AND SYSTEM SETUP ( ✱ 77 – ✱ 93)
✱ 77 DAYLIGHT SAVINGS TIME
START\END MONTH
✱ 78 DAYLIGHT SAVINGS TIME
START\END WEEKEND
∗ 79, *80, *81, *82
MENU MODES
✱ 84
AUTO STAY ARM
✱ 85
CROSS ZONE TIMER
This option not for use in UL installations.
✱ 86
CANCEL VERIFY KEYPAD DISPLAY
✱ 87
MISC. FAULT DELAY TIME
(used with Configurable Zone Types "digit 6")
✱ 88
PROGRAM MODE LOCKOUT
OPTIONS
✱ 89
EVENT LOG FULL REPORT CODE
✱ 90
EVENT LOG ENABLES
✱ 91
OPTION SELECTION
[0,0,0]
Part. 1 Part. 2 Common
Away Stay
Away Stay
Part. 1
Part. 2
|
[00]
|
[00]
[0]
|
[00]
|
[00]
|
[00]
|
[00]
|
[00]
|
[00]
|
[4][10]
|
[1][5]
These are Menu Mode commands, not data fields, for Output Device Mapping, Output
Programming, Zone List Programming, and Alpha Programming respectively. See page
2 and their respective sections in the Installation and Setup Guide for procedures.
[3]
[0]
(assign cross zones on
zone list 4, using *81 Menu
mode)
[1]
[0]
UL: may only be used on
non-burglar alarm/ non-fire
alarm zones when used in
fire and/or UL burglar alarm
installation
[0]
|
[00]
[3]
NOTE : System messages are
logged when any non-zero
selection is made.
[8]
SIA Installations: Exit Delay
should be enabled.
– 5 –
See box above.
[0,0,0,0,0,0] See box above.
Away Stay
Common
See box on previous page.
UL: must be enabled if wireless devices are used
See box on previous page.
See box on previous page.
See box on previous page.
See box on previous page.
See box on previous page.
See box on previous page.
See box on previous page.
UL: must be enabled if wireless devices are used
See box on previous page.
0 = Disabled
1-12 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
0 = disabled, 1 = first, 2 = second, 3 = third
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
0 = no, 1 = partition 1 only
2 = partition 2 only, 3 = both partitions
0 = 15 seconds
6 = 2-1/2 min
1 = 30 seconds
7 = 3 min
2 = 45 seconds
8 = 4 min
3 = 60 seconds
9 = 5 min
4 = 90 seconds
#+10 = 6 min
5 = 2 minutes
#+11 = 7 min
0 = no, 1 = yes
0 = 15 seconds
6 = 2-1/2 min
1 = 30 seconds
7 = 3 min
2 = 45 seconds
8 = 4 min
3 = 60 seconds
9 = 5 min
4 = 90 seconds
#+10 = 6 min
5 = 2 minutes
#+11 = 7 min
0 = standard *98 installer code lockout (reentry only by
downloader or [∗] + [#] within 50 secs after power up)
1 = lockout [∗] + [#] reentry after *98 exit (reenter via
installer code or downloader only)
2 = not used
3 = lockout all local programming after *98 exit (reentry
via downloader only)
See box on previous page for report code entries.
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close.
Example: To select "Alarm/Alarm Restore", and
"Open/Close", enter 9 (1 + 8); To select all, enter #15.
0 = None
2 = Sounder Delay (delays sounding by 15 seconds)
UL: if used, entry delay (*35) must be 30 sec. max.
4 = AAV UL: must use ADEMCO UVCM module
8 = Exit Delay Restart/Reset UL: must be disabled
#+12 = AAV and Exit Delay Restart/Reset
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min