CONTROLLER OPERATION

ADJUSTING TEMPERATURE (Temporary Override when in Programmable mode)
1.
Before you can adjust the temperature, a MODE must be selected. If you are already in a Heating or Cooling mode, then skip to
step 5.
2.
To select a MODE, use the keypad arrows to scroll to MODE, and then press the center button ■ on the key pad to enter the
operating mode menu.
3.
Select the desired mode by scrolling up or down, with the arrows ▲▼, and then press the center button ■ on the keypad to
enter into that mode.
4.
You are now returned to the Main Menu and Figure 1 is a similar view. NOTE:
is installed.
5.
To increase the temperature set point, use the arrow up button ▲. To decrease the set point, use the arrow down button ▼. Press the center
button ■ on the key pad for the new set point to be effective.
SETTING DATE AND TIME
Menu Driven Display
1120-445
Outdoor temperature is only displayed if an outdoor sensor
1.
From the Main Menu, scroll to MENU and press the center button ■
on the keypad.
8/08/05
8:45 AM
OUTDOOR
FAN AUTO
93°
HEATING
73°
AUTO
SETPOINT
HEAT 62
COOL 85
TEMP
RH
MODE
FAN
MENU
Figure1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8403-060 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bard 8403-060

  • Page 1 997-060180-4e User’s Manual 8403-060 Menu Driven Display 1120-445 CONTROLLER OPERATION 8/08/05 8:45 AM OUTDOOR FAN AUTO ADJUSTING TEMPERATURE (Temporary Override when in Programmable mode) 93° HEATING Before you can adjust the temperature, a MODE must be selected. If you are already in a Heating or Cooling mode, then skip to 73°...
  • Page 2 997-060180-4d Select SET DATE AND TIME Select FAN. If your area observes daylight savings time, select AUTO Select the operation you desire as described above. DAYLIGHT SAVING, scroll to ON, then press the center button ■ to save. You will be returned to the select SET DATE AND TIME CHANGING MODES menu.
  • Page 3 997-060180-4d the MODE to OFF, and then back to the operating mode, If you selected TEMP ADJUST ONLY, you will only be able to typically AUTO. adjust the set point temperature. Any other operation will require the If step 3 is not done within 10-minutes the display will pin number to unlock the controller.
  • Page 4: Advanced Features

    997-060180-4d NOTE: - If CS2000A is installed, the controller will inhibit all outputs INSTALLER except the Y0/D when there is no 24Vac applied to the L input on the thermostat. When the CS2000A is not installed, the L input is the Lock out ADVANCED FEATURES INFORMATION / signal from the heat pump.
  • Page 5 997-060180-4d FULL TIME DEHUMIDIFY - Turns on the D output when the make this period of time an event and set the thermostat at an energy room humidity is above the set humidity level all the time. saving setting. You have the option of setting the events per day to 4- NONE –...
  • Page 6 If the system is equipped with an optional outdoor temperature sensor, wire inside the thermostat plastic case may interfere with the air flow across Bard PN 8403-061(1125-2), it is possible to allow the controller to operate the temperature sensor. the heat pump system in the most efficient manner possible. By setting the...
  • Page 7 NOTES 997-060180-4d...