2) Tracking balance adjustment
3) Gain adjustment (The gain is compensated inside the IC so that the
loop gain at the gain crossover frequency will be 0 dB.)
* Focus gain adjustment
* Tracking gain adjustment
4. CD ERROR CODE DESCRIPTION
Error
01
When Pickup set inner position, inner switch cannot detect
'ON' level for 10 secs.
10*
CAM error. Can't detect CAM switch when CAM is moving.
11*
When it detect cam operation error during initialize process.
20*
TRAY error. Can't detect TRAY switch when TRAY is mov-
ing.
21*
When it detect TRAY operation error during initialize pro-
cess.
22*
When it detect invalid TRAY switch during normal operation.
31
When it change to CD function, DSP cannot read initial data.
* 'CHECKING'
If Error is detected, 'CHECKING' will be displayed instead of 'ER-
CD**'. 'ER-CD**' display will only be displayed when error had been
detected for the 5th times.