Fan - Vaillant TURBOmax Pro 28/2 E Instructions For Installation And Servicing

Wall hung room sealed fan assisted combination boilers
Table of Contents

Advertisement

PARTS REPLACEMENT

Fan

Refer to the important information
and initial preparation on page 45.
Remove combustion chamber cover
by unclipping the three clamps (1).
Remove the screw (3) and push the
2
flue connector (4) upwards until it
clears the fan outlet (when the
boiler is installed with a rear outlet
1
flue system push the flue connector
(4) towards the rear of the boiler
until it clears the fan outlet).
Disconnect the electrical
connections (5) and the air tubes (6
and 7) from the fan. Note the
respective connection points for
each tube.
Remove two screws (8) and remove
the fan (9).
Reassemble in reverse order,
ensuring that the air tubes are
4
5
reconnected to the correct nipple.
3
Re-fit combustion chamber cover
and front casing.
6
7
8
9
Fig. E.4: Fan
47