STEP 6
PREPARE FOR DUCTWORK
NOTE: Ductwork MUST be vented outside.
DO NOT vent into a wall, ceiling, crawlspace,
attic or any concealed space.
Determine the best route for ductwork; it can
be routed in a variety of ways depending on the
kitchen layout.
Typical duct arrangement countertop series.
Inside wall
"
"
3
1
X10
cabinet
4
(8.2 cm X 25.4 cm)
Transition elbow
Up inside wall to roof or
overhang.
Peninsula or island
Between floor joists.
Optional duct arrangement under concrete slab.
NOTE: PVC sewer pipe type PSM 12454-B
Schedule 40 ASTM D1785.
Wall cap
12"
(30 cm)
Min.
6"
(15 cm)
Dia. PVC
coupling
6" (15 cm) Dia.
Pack tightly with gravel
PVC Sewer pipe
or sand completely
elbow
around pipe.
22
INSTALLATION INSTRUCTIONS
Outside wall
cabinet
Directly to outside.
Peninsula
3
1
"
X10
"
4
(8.2 cm X 25.4 cm)
Thru cabinet toe space.
5" to 6"
(12.7 cm to 15 cm)
6" (15 cm)
Metal transition
Dia. 90°
Metal Elbow
Concrete
6" (15 cm) Dia.
slab
Metal Duct
16"
6" (15 cm)
(40.6 cm)
Dia. PVC
Max.
Sewer Pipe
30" (76.2 cm)-0" Max
6" (15 cm) Dia.
PVC Sewer pipe
elbow
(continued)
STEP 7
GAS CONNECTION
Make the gas connection
to the inlet of the
pressure regulator on this
appliance with a 1/2" pipe
nipple with male pipe
thread. Use an approved
pipe joint compound
resistant to the action
of LP gas at pipe
connections.
Install a manual shut-off
valve in the gas line in an
easily accessible location,
as close to the pipe stub
as possible, making
allowances for the
ventilation ducting.
Be sure you know how
and where to shut off the
gas supply to the cooktop.
NOTE:
Instead of using solid piping to connect to
pressure regulator, an approved flexible metal
appliance connector may be used between the
pipe stub and shut off valve and the pressure
regulator, if local codes permit.
Transition
Appropriate flare union adapters are required at
elbow
each end of the flexible connector.
Turn on the gas; check for leaks using a liquid
leak detector at all joints in the system.
CAUTION: DO NOT USE A FLAME
TO CHECK FOR GAS LEAKS.
IMPORTANT—Disconnect the cooktop and the
6" (15 cm)
individual shut off valve from the gas supply
Dia. Metal
piping system during any pressure testing of that
duct
system at test pressures greater than
Isolate the cooktop from the gas supply piping
system by closing the individual manual shut off
valve to the cooktop during any pressure testing
of the gas supply piping system at test pressures
6"
equal to or less than
(15 cm)
Dia.
PVC
coupling
6" (15 cm)
Dia. PVC
Sewer
pipe
Gas appliance
pressure
regulator
1/2" Threaded
pipe nipple
Shut-off valve
Pipe stub
1
PSIG.
2
PSIG.
1
2

Advertisement