8. Replacing the burner-jet ( E Fig. 1 2 )
Unscrew union nut (F, Fig. 12) of gas pipe by using a lo mm fork-spanner
1.
and a second one (14 mm) to hold counterpart the jet.
Unscrew burner jet from the bottom part of gas-burner.
2.
Screw in the new burner jet, refit gas pipe.
3.
IMPORTANT: The

9. Cooling unit replacement.

_________
1.
Unscrew thermo-coupling (I, Fig.11) from thermo-current adapter (J,Fig.ll).
2.
Unscrew clip (0, Fig.11) for gas-pipe (G, Fig.11) and thermocouple.
3.
Remove the three connections (A, Fig. 13/R, Fig.ll), unscrew support
bracket (B, Fig. 13) of the ventilator.
4.
Unscrew thermostat (S, Fig. 11) from condenser fins and remove plug-connec-
tion of grounding cable (T, Fig. 11) above the condenser fins.
Squeeze the heater insulation in direction of arrow (A, Fig.8) until it
5.
clicks open. Pull open the insulation in direction of arrow (B, Fig. 8)
and remove it.
6.
Unscrew fixing screw (C, Fig.8) of the heater and remove the heater from
its pocket by pulling straight up.
7.
Unscrew union nut (A, Fig. 14) of flexible exhaust pipe (B, Fig. 14)using
a pipe wrench, remove flexible pipe and gasket from gas heating-pipe (C,Fig.l4).
8.
Unscrew union nut (U, Fig.11) from air feed-pipe.
9.
Unscrew six screws (A, Fig.15) from the bottom part of gas burner and two
screws from support bracket (B, Fig.15) of the drainage tube (C, Fig. 15).
lo. Take off bottom part of burner with thermocouple, gas pipe and spark igni-
tor with cable from upper part of burner (D, Fig.15) by withdrawing to the
right side .
11. Unscrew upper part of gas burner (D, Fig.15) with air inlet pipe (E, Fig.15)
fran the gas heating pipe (F, Fig.15) (2 screws G, Fig. 15).
12. Unscrew locking plate from pilot sight peep (H, Fig.15).
13. Unscrew eight screws (I, Fig. 15) from the cooling unit attachment panel 'and
take cooling unit out of the cabinet.
14. For the installation of the cooling unit, proceed in the reverse sequence.
CAUTION: The location of the thermostat capillary tube should be noted at
IMPORTANT
www.westfaliaT3.info - a useful site for enthusiasts and owners of VW Westfalia T25 / T3 / Vanagon campers
___
gasket (G, Fig.12) between the lower part of the burner and
the burner-jet must be replaced by a new one and carefully posi-
tioned to ensure that the burner is properly sealed.
________
this time for relocation later on. The tubes must be placed in the
correct position otherwise, improper p e r f o r m a n c e will result..
gasket (H, Fig.12) between the lower and upper part of the
:
The
burner must be replaced by a new one and carefully positioned
to ensure that the burner is properly sealed.
Also the gasket (I, Fig.12) between the upper part of the bur-
ner and the gas heating pipe should be replaced too.