Imperx IPX CAMERA SERIES User Manual page 66

High-resolution, programmable 8/10/12 bit, camera link digital cameras
Table of Contents

Advertisement

VCCD
CAUTION NOTE
1.
2.
3.
4.
5.
6.
www.imperx.com
Frame rate [fps] = 1 / long integration time [sec]
Long Integration Time
Standard Frame Time
Figure 2.30 - Long Integration
During
the integration time the camera has to be kept still otherwise a
motion
smear will appear on the image.
The minimum value for long integration is camera dependent:
-
IPX-VGA210/210 – 10 ms.
-
IPX-1M48 – 30 ms.
-
IPX-2M30/H – 70 ms.
-
IPX-4M15 – 120 ms.
-
IPX-11M5 – 420 ms.
Long Integration cannot be enabled in Trigger mode.
Long Integration cannot be enabled in Programmable Frame Rate
mode.
Long Integration cannot be enabled in Shutter mode.
Long time integration significantly decreases the signal
More electrons will be collected from the pixels dark current and thus
the camera noise will increase significantly.
of
66
137
IPX Manual RB01
(4.2)
to
noise ratio.
5/6/2005