Installation Instructions

For the way it's made
Write down the model and serial numbers
before installing cooktop.
Both numbers are on the model/serial
rating plate, located on the bottom of the
cooktop.
Model #___________________________
Serial # ___________________________
®
®
Questions regarding features,
operation, performance, parts or
service? Call 1-800-422-1230 or visit
our web site at www.kitchenaid.com
Part No. 8285364

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid 8285364

  • Page 1: Installation Instructions

    Both numbers are on the model/serial rating plate, located on the bottom of the cooktop. Model #___________________________ Serial # ___________________________ ® ® Questions regarding features, operation, performance, parts or service? Call 1-800-422-1230 or visit our web site at www.kitchenaid.com Part No. 8285364...
  • Page 2: Tools And Materials Needed For Installation

    • Comply with the electrical specifications on the model/serial rating plate. Model/serial rating plate is located on the bottom of the cooktop. Write both numbers down on the front cover now before installing cooktop. Downdraft cooktop location should be...
  • Page 3: Cutout Dimensions

    0" (0 cm) clearance. New installations — Follow minimum dimensions given. Replacement installation — Be sure that front edge of cooktop is at least 1-1/2" (38.1 mm) back from front edge of countertop. cutout width If cabinet has drawers, drawers will need to be removed and drawer fronts installed on front of cabinet.
  • Page 4: Venting Methods

    Flexible metal vent is Not recommended. The cooktop may be vented through the wall or floor. Common venting methods and the types of materials needed are shown. Make sure there is proper clearance within the wall or floor for exhaust vent before 17"...
  • Page 5 6" (15.2 cm) round metal vent 6" (15.2 cm) wall round PVC sewer pipe 16" (40.6 cm) 12" (30.5 cm) maximum minimum 6" (15.2 cm) round PVC coupling 30" (76.2 cm) max. 6" (15.2 cm) Tightly pack gravel or sand round 90°...
  • Page 6: Electrical Requirements

    3/4" (19.1 mm) from rear wall as recommended. side edge of cooktop is at least 6 inches (15.2 cm) from side wall. Locate the junction box to allow as...
  • Page 7: Electrical Connection

    See Figure 2. 8. Replace junction box cover. You have just finished installing your new KitchenAid downdraft cooktop. To get the most efficient use from your new cooktop, read your Use & Care Guide.
  • Page 8: Cooktop Removal

    Both numbers can be found on the model/serial rating plate located on the bottom of the cooktop. Prepared by KitchenAid, Benton Harbor, Michigan 49022 If you need service: Consult your Use & Care Guide. In the event that your KitchenAid...
  • Page 9: Instructions D'installation

    N ° de modèle N ° de série ® ® Pour des questions concernant les caractéristiques, le fonctionnement, la performance, les pièces, accessoires ou le service, composer le 1-800-422-1230 ou consulter www.kitchenaid.com N ° de pièce 8285364...
  • Page 10: Pièces Fournies

    Avant de commencer... Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole de sécurité.
  • Page 11: Dimensions Du Produit

    Dimensions du produit largeur de 80 cm (31 1/2 po) - table de profondeur largeur de 95,3 cm (37 1/2 po) - table de 54,4 cm (21 13/16 po) profondeur du ventilateur de 37,1 cm (14 5/8 po) câble d’alimentation électrique de 91,4 cm (3 pi) de long installé...
  • Page 12 Prescriptions concernant le système d’évacuation Le système doit décharger l’air à l’extérieur. Ne pas terminer le conduit d’évacuation au-dessus d’un plafond ou dans un autre espace fermé. Ne pas utiliser une bouche de décharge murale de 10 cm (4 po) normalement utilisée pour un équipement de buanderie.
  • Page 13 conduit métallique diam. 15,2 cm (6 po) tuyau PVC/ bouche de égout diam. décharge 15,2 cm (6 po) murale 40,6 cm (16 po) 30,5 cm (12 po) maximum minimum raccord PVC diam. 15,2 cm (6 po) coude 90° 76,2 cm (30 po) PVC/égout, diam.
  • Page 14: Spécifications Électriques

    Spécifications électriques Si un conducteur distinct de liaison à la terre est utilisé lorsque le code le permet, on recommande qu’un électricien qualifié vérifie que la liaison à la terre est adéquate. Ne pas utiliser une tuyauterie de gaz pour la liaison à la terre. En cas d’incertitude quant à...
  • Page 15: Raccordement Électrique

    8. Réinstaller le couvercle de la boîte de connexion. Vous avez terminé l’installation de votre nouvelle table de cuisson KitchenAid à aspiration vers le bas. Pour obtenir l’utilisation la plus efficace de votre nouvelle table de cuisson, veuillez lire le Guide d’utilisation et d’entretien.
  • Page 16: Table De Cuisson

    Les deux numéros se trouvent sur la plaque signalétique située à la base de la table de cuisson. Préparé par KitchenAid, Benton Harbor, Michigan 49022 Si vous avez besoin de service : Consulter votre Guide d'utilisation et d'entretien Dans l’éventualité...