Rear Panel Connections - General DataComm Metroplex 6000 MP 6960 Installation And Operation Manual

Wallmount enclosure
Table of Contents

Advertisement

Wallmount Enclosure
1.
Locate the wallmount plate on the plywood panel and level the plate.
2.
Mark the position of the two keyhole slots and the two mounting holes.
3.
Using the wood screws provided, screw two into panel at the keyhole positions leaving
about 1/4" protruding. The holes located at the bottom of the wallmount plate are used for
additional securing. Tighten all four screws.
4.
The enclosure can now be attached to the wallmount plate by aligning the chassis plate slots
with the wallmount plate tabs and moving the enclosure to the right and down.

Rear Panel Connections

The following paragraphs describe the rear panel connections to the Wallmount Enclosure. See
Figure 1-3.
Figure 1-3
All line interface and voice and data channel cabling is made directly to connectors on each cards
front panel. However, some power and ground connections are made on the rear panel. Behind
the rear bezel are two terminal blocks. Terminal block 1 (TB1) is a four-position block and is not
used. Terminal block 2 (TB2) is a six-position block that is used for ground connections and for
external power input.
IEC 320 AC Power Input
Rear Panel Connections
Terminal Block
(under cover)
Chassis Grounding Post
1-5
GDC 086R601-001