STEP FIVE:
Reinstall the Tank
MCR29633
M29628A
Steam Humidifier System 69-2285—09
1
2
3
4
Before reinstalling the tank and cover, perform
these checks:
Clear any dust from the ventilation holes
in the cover.
Clear any debris from the water drain tube.
Make sure the water tank gasket seal is seated
properly in the steam humidifier base. Make sure
the gasket is in good condition (no cracks or tears)
before attaching the tank.
Attach tank by securing the latch and plug
in steam humidifier.
If the control is calling for humidity, the humidifying light
will blink at startup. Steam humidifier waits 5 minutes
to complete the tank reconnection before acting on this
call.
Engage the white water valve to the tank's black
spool, then turn the manual shutoff valve to the "Lock"
position and plug in the power cord.
Check that steam humidifier is still mounted level and
is securely in place on the mounting bracket.
Press the Go button once the tank is completely
reconnected. This will ready steam humidifier to act on
the control's call for humidity (if present).
49